First-in-Human Intratumoral Temperature Monitoring During Standard 3 T MRI Demonstrates RF-Induced Tissue Heating Within Clinical Safety Limits.

Chie-Hee Cho, Franz Bergholz, Lutz Lüdemann, Carlo Bergholz, Emma Winger, Pauline Brand, Christian Spiegel, Wolfram Weschenfelder, Nikolaus Gaßler, Anna Xylander and 3 more

Abstract readCase Reports
In one paragraph

Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

13 authors.

Chie-Hee ChoInstitute for Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
Franz BergholzInstitute for Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
Lutz LüdemannDepartment of Medical Physics, Clinic for Radiationtherapy, University Hospital Essen, 45147 Essen, Germany.
Carlo BergholzExperimental Radiology, Jena University Hospital, 07747 Jena, Germany.
Emma WingerExperimental Traumatology, Jena University Hospital, 07747 Jena, Germany.
Pauline BrandInstitute for Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, 07747 Jena, Germany.
Christian SpiegelDepartment of Trauma, Hand and Reconstructive Surgery and Orthopedics, Clinic for Trauma, Jena University Hospital, 07747 Jena, Germany.
Wolfram WeschenfelderDepartment of Trauma, Hand and Reconstructive Surgery and Orthopedics, Clinic for Trauma, Jena University Hospital, 07747 Jena, Germany.ORCID 0000-0002-4828-1812
Nikolaus GaßlerSection of Pathology, Institute for Forensic Medicine, Jena University Hospital, 07747 Jena, Germany.
Anna XylanderSection of Pathology, Institute for Forensic Medicine, Jena University Hospital, 07747 Jena, Germany.
Ingrid HilgerExperimental Radiology, Jena University Hospital, 07747 Jena, Germany.ORCID 0000-0003-1811-6450
Britt WildemannExperimental Traumatology, Jena University Hospital, 07747 Jena, Germany.ORCID 0000-0002-8365-1188
Gunther O HofmannDepartment of Trauma, Hand and Reconstructive Surgery and Orthopedics, Clinic for Trauma, Jena University Hospital, 07747 Jena, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Magnetic resonance imaging (MRI) uses radiofrequency (RF) energy to generate diagnostic images. RF-tissue interactions lead to energy absorption and tissue heating, quantified by the specific absorption rate (SAR). Although SAR limits are strictly regulated for patient safety, actual in vivo tissue temperature changes during clinical MRI examinations in humans have not been directly measured. A patient with a histologically confirmed soft tissue sarcoma of the thigh underwent a clinically indicated 3 T MRI examination 24 h prior to resection. During imaging with whole-body SAR of 2.27 W/kg, direct temperature measurements (invasive and on the skin) were obtained. Temperatures increased by 2.0 °C within the tumor and at the skin surface was 3.4 °C at the skin surface. No technical difficulties or adverse events were observed, and the patient tolerated the examination well. This first-in-human case demonstrates the feasibility and safety of direct intratumoral temperature measurement during standard 3T MRI. While MRI was performed within safety limits of SAR as a surrogate for true tissue temperature, non-invasive temperature monitoring during MRI needs improvement. Controlled RF-induced heating during MRI may open new therapeutic possibilities, including MR-guided hyperthermia for sarcomas and other solid tumors or modulation of blood-brain barrier through transient RF-induced temperature elevations facilitating drug delivery.

Indexed as

hyperthermiaintratumoral temperature measurementmagnetic resonance imagingradiofrequency induced heatingradiofrequency radiationsoft tissue sarcomaspecific absorption ratetherapeuticsthermometry

Identifiers

PMID42510423
PMCPMC13405237

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.