ArticleBioengineering (Basel, Switzerland)2026
The Effects of Multiple Use and Sterilization on the Accuracy of Readings of Different Types of Torque Controllers.
Article in Bioengineering (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Application of the appropriate torque in implant prosthodontics is very important from a clinical perspective. In implant prosthodontics, three basic types of torque wrenches are used. There are few reports in the dental literature on the possibility of controlling the torque generated by the wrench. The aim of this study was to determine the precision of measurements of various types of torque wrenches after the specified number of application and sterilization cycles. The materials consisted of 22 torque wrenches (10 spring-type, 6 toggle-type, and 6 contra-angle-type). The research methodology included measuring the accuracy of torque value indications using the gravity method. The research was conducted for different torque ranges for brand new wrenches and after 50 and 100 sterilization cycles. After each sterilization cycle, the wrenches were used to generate torque several times. Results: Before sterilization, the spring-type torque controllers were characterized by the lowest accuracy (in the largest range at low torque). The average deviation for contra-angle-type and toggle-type wrenches was smaller. After sterilization cycles, the toggle-type wrenches showed the smallest changes in measurement precision. Conclusions: The effects of multiple use and sterilization on the accuracy of readings of different types of torque controllers seem limited overall; the greatest stability of measurement accuracy was demonstrated by the toggle-type wrenches, while the spring-type wrenches presented the greatest decrease in measurement precision.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.