Evidence map›Paper›PMID 42509453›Full record

ArticleJournal of ultrasound2026

Diagnostic accuracy of contrast-enhanced ultrasound versus duplex ultrasound and computed tomography angiography for endoleak detection after EVAR: a prospective comparative study.

Wellington Gianoti Lustre, Libnah Leal, Vinicius Cardoso, Mateus Aves Borges Cristino, Carolina Dutra Queiroz Flumignan, Ronald Luiz Gomes Flumignan, Jorge Eduardo de Amorim, Luis Carlos Uta Nakano

Abstract readComparative Study
In one paragraph

Article in Journal of ultrasound, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wellington Gianoti LustreDivision of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil.ORCID http://orcid.org/0000-0001-6488-0826
Libnah LealDivision of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil.ORCID http://orcid.org/0000-0001-9563-8047
Vinicius CardosoDivision of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil.
Mateus Aves Borges CristinoDivision of Vascular Surgery, Hospital Mater Dei, Belo Horizonte, Brazil.ORCID http://orcid.org/0000-0001-9487-9770
Carolina Dutra Queiroz FlumignanDivision of Vascular Surgery, Centro Universitario Sao Camilo, São Paulo, Brazil.ORCID http://orcid.org/0000-0001-9943-3583
Ronald Luiz Gomes FlumignanDivision of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil. flumignan@unifesp.br.ORCID http://orcid.org/0000-0001-6440-8011
Jorge Eduardo de AmorimDivision of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil.
Luis Carlos Uta NakanoDivision of Vascular and Endovascular Surgery, Universidade Federal de São Paulo, 754, Rua Borges Lagoa, Vila Clementino, São Paulo, SP, 04038-001, Brazil.ORCID http://orcid.org/0000-0002-7996-3269

Funding

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior 919526
6 · The paper itself

Abstract

backgroundLifelong imaging surveillance after endovascular aneurysm repair (EVAR) is essential for endoleak detection but is limited by cumulative radiation and nephrotoxicity from computed tomography angiography (CTA). Contrast-enhanced ultrasound (CEUS) has emerged as a promising alternative, although prospective comparative data remain limited.

methodsIn this prospective, single-centre diagnostic accuracy study, 30 consecutive patients (mean age 78.5 ± 7.1 years; 70% male) undergoing EVAR follow-up were evaluated with duplex ultrasound (DUS), CEUS (SonoVue®), and CTA within a 30-day interval. CTA served as the reference standard. Diagnostic performance metrics were calculated with 95% confidence intervals (CIs) according to STARD recommendations.

resultsEndoleaks were identified in 11 patients (36.7%). CTA detected 8 cases (26.7%), CEUS 9 (30.0%), and DUS 4 (13.3%). CEUS demonstrated high sensitivity (87.5%; 95% CI 47.3-99.7%) and specificity (90.9%; 70.8-98.9%), with overall accuracy of 90.0% (73.5-97.9%). In contrast, DUS showed limited sensitivity (33.3%; 9.9-65.1%) despite perfect specificity (100%), yielding lower accuracy (73.3%). Inter-modality agreement was 83.3%.

conclusionsCEUS demonstrates high diagnostic accuracy for endoleak detection after EVAR and represents a robust, radiation-free alternative to CTA for longitudinal surveillance. Given its favourable safety profile and diagnostic performance, CEUS should be considered a first-line imaging modality in routine follow-up, with CTA reserved for equivocal findings or pre-interventional planning. These results support a paradigm shift toward CEUS-based surveillance strategies.

Indexed as

Computed Tomography AngiographyContrast MediaEndoleakEndovascular Aneurysm RepairUltrasonography, Doppler, DuplexAgedAged, 80 and overAortic Aneurysm, AbdominalFemaleHumansMalePhospholipidsProspective StudiesSensitivity and SpecificitySulfur HexafluorideUltrasonographycontrast agent BR1Contrast MediaPhospholipidsSulfur HexafluorideAbdominal aortic aneurysmComputed tomography angiographyContrast-enhanced ultrasoundDiagnostic accuracyDuplex ultrasoundEndovascular aortic repair

Identifiers

PMID42509453
PMCPMC13588977

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.