Static and Dynamic Mechanical Properties of 3D-Printable Aligner Resins: An In Vitro Study with FTIR Chemical Characterization.

Marco Serafin, Elisa Boccalari, Marina Borgese, Alberto Caprioglio, Mario Raspanti, Gilberto Binda, Piero Antonio Zecca

Abstract read
In one paragraph

Article in Journal of functional biomaterials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Marco SerafinDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy.ORCID 0000-0003-4680-0989
Elisa BoccalariDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy.ORCID 0000-0001-5078-7284
Marina BorgeseDepartment of Medicine and Innovative Technology, University of Insubria, 21000 Varese, Italy.ORCID 0009-0005-0723-6424
Alberto CaprioglioDepartment of Biomedical, Surgical and Dental Sciences, University of Milan, 20122 Milan, Italy.ORCID 0000-0002-8264-7320
Mario RaspantiDepartment of Medicine and Innovative Technology, University of Insubria, 21000 Varese, Italy.ORCID 0000-0001-6322-1845
Gilberto BindaDepartment of Science and High Technology, University of Insubria, 22100 Como, Italy.ORCID 0000-0001-5530-3939
Piero Antonio ZeccaDepartment of Medicine and Innovative Technology, University of Insubria, 21000 Varese, Italy.ORCID 0000-0001-9646-4958

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDirectly printed aligners are advancing rapidly, but the mechanical behavior of the resins behind them is still only partly understood. This in vitro study compared the static flexural behavior, short-term stress relaxation, and FTIR profiles of five Class IIa-certified 3D-printable resins for direct orthodontic aligners.

methodsThe five resins, TC-85, TA-28, DCA, Clear-A V2, and Ortho Flex, were printed as standardized rectangular bars and tested at 37 °C. Three-point bending to 1 mm deflection yielded the maximum flexural stress and the flexural modulus, while a 30 min hold at fixed deflection captured stress relaxation. FTIR added a qualitative chemical characterization.

resultsDifferences between resins were substantial. DCA led on every static measure, pairing the highest flexural stress and modulus with the highest final relaxation modulus and the best stiffness retention. Clear-A V2 was also statically stiff but retained force only intermediately, whereas TC-85 combined high stiffness with pronounced relaxation. Ortho Flex performed modestly under static loading yet held on to a moderate fraction of its stiffness, and TA-28 relaxed the most.

conclusionsDirectly printed aligner resins are mechanically heterogeneous, and static bending alone did not predict short-term force stability. Relaxation metrics should therefore accompany static testing whenever a resin is selected for a specific clinical purpose.

Indexed as

3D printable resinsFTIR spectroscopymechanical propertiesorthodontic alignersthree-point bending test