Evidence map›Paper›PMID 42504745›Full record

ArticleMagnetic resonance in medicine2026

Image-Derived Volumetry During Forced Expiration Using a 3D Fermat Looped, Orthogonally Encoded Trajectory.

Sebastian Scheidel, Viktor Hartung, Matthias Stephan Anders, Corona Metz, Herbert Köstler, Simon Veldhoen, Tobias Wech

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Sebastian ScheidelDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID https://orcid.org/0009-0001-7156-2647
Viktor HartungDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID https://orcid.org/0000-0002-6273-9172
Matthias Stephan AndersDepartment of Pediatric Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.ORCID https://orcid.org/0000-0002-6447-2029
Corona MetzDepartment of Pediatric Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.ORCID https://orcid.org/0000-0002-4118-3275
Herbert KöstlerDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID https://orcid.org/0000-0001-6207-9226
Simon VeldhoenDepartment of Pediatric Radiology, Charité-Universitätsmedizin Berlin, Corporate Member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Berlin, Germany.ORCID https://orcid.org/0000-0002-3585-5442
Tobias WechDepartment of Diagnostic and Interventional Radiology, University Hospital Würzburg, Würzburg, Germany.ORCID https://orcid.org/0000-0002-2813-7100

Funding

German Research Foundation 535829883
6 · The paper itself

Abstract

purposeTo enable MRI-based nongated 3D depiction of forced expiration with both high spatio-temporal resolution and fidelity of lung dynamics.

methodsAn undersampled 3D Fermat looped, orthogonally encoded trajectory (FLORET) was optimized for nonsegmented dynamic acquisitions during forced expiration and a corresponding model-based reconstruction pipeline promoting spatial and temporal total variation was implemented. The approach was first optimized and validated using a lung phantom, specifically constructed for this study and was then translated to in vivo measurements. This allowed high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm.

resultsVolumes derived by segmenting the MR images of the phantom demonstrated excellent agreement with the air exchange measured directly at the phantom within the bore, therefore confirming the validity of the approach. In both phantom and in vivo experiments, the dynamic deflation process could be successfully depicted, confirming the potential for assessing forced expiration with 3D UTE FLORET MRI. From the segmented volumes in vivo, quantitative parameters were derived, including the duration of the dynamic phase (2.8 ± 0.2 s), the time to 90% deflation (1.8 ± 0.2 s), and the volume change within the first second (2.8 ± 0.2 L).

conclusionThe phantom and in vivo studies demonstrate, that the 3D FLORET trajectory can be utilized to study lung deflation during forced expiration with high temporal resolution of 200 ms and isotropic spatial resolution of 5 mm using a TV-regularized primal-dual SENSE reconstruction. Acquisitions were performed for discrete distinct time frames, that is, no segmented k-space filling across several respiratory cycles was used.

Indexed as

ExhalationImage Interpretation, Computer-AssistedImaging, Three-DimensionalLungMagnetic Resonance ImagingAlgorithmsHumansImage EnhancementPhantoms, ImagingReproducibility of ResultsSensitivity and Specificitycompressed sensingforced expirationlung imagingspirometry

Identifiers

PMID42504745
PMCPMC13619860

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked