Evidence map›Paper›PMID 42504564›Full record

ArticleThe Analyst2026

Leveraging image processing techniques to visualize sub-cellular domains in optical photothermal infrared imaging.

Elisabeth Holub, Nikolaus Hondl, Margaux Petay, Sarah Reindl, Sophie Honeder, Tamara Tomin, Bernhard Lendl, Georg Ramer

Abstract read
In one paragraph

Article in The Analyst, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Elisabeth HolubTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0009-0006-0703-9524
Nikolaus HondlTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0009-0001-9282-4474
Margaux PetayTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0000-0002-5513-6074
Sarah ReindlTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0009-0004-7025-3078
Sophie HonederTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0000-0002-7201-6293
Tamara TominTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0000-0002-7071-2316
Bernhard LendlTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0000-0003-3838-5842
Georg RamerTU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9, 1060 Wien, Austria.ORCID http://orcid.org/0000-0001-8307-5435

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Traditionally, vibrational spectroscopic imaging captures a full spectrum at every pixel, a technique commonly referred to as hyperspectral imaging. With the emergence of high-resolution vibrational imaging methods such as optical photothermal infrared (O-PTIR) spectroscopy, it has become a widespread practice to perform imaging at specific wavenumber settings instead of acquiring full hyperspectral data cubes to speed up the acquisition process. Yet, regardless of the dimensionality of the data, spectroscopic imaging modalities require elaborate data pre-processing to reduce background noise, scattering effects, and imaging artifacts that may otherwise distort chemical information and prevent the reliable implementation of feature extraction and classification algorithms. Although the spectral analysis of chemical images has been extensively studied, there is limited research on spatial pre-processing techniques such as masking and spatial filtering, which may become more important when images are acquired at select wavenumbers only. Furthermore, processing pipelines are often vendor-specific, hampering the comparability of research results, or rely on bespoke algorithms and non-standard dependencies, leading to long-term maintenance and compatibility issues. The aim of this paper is hence to present a straightforward, step-by-step protocol for the spatial processing and subsequent segmentation of sparse chemical imaging data using standard open-source libraries. We demonstrate our approach on a set of single-wavenumber images of human cells recorded with a home-built O-PTIR instrument.

Identifiers

PMID42504564
PMCPMC13403074

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.