Evidence map›Paper›PMID 42503837›Full record

ArticleMagnetic resonance in medicine2026

Enhanced Transmit Efficiency of a Loop Array Combined With Out-of-Phase Passive Dipoles for Thoracic Spinal Cord MRI at 7T.

Hugo Amat, Marc Dubois, Aurelien Destruel, Sajad Hosseinnezhadian, Djamel Berrahou, Charles Betemps, Amira Trabelsi, David Bendahan, Stefan Enoch, Virginie Callot and 1 more

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Hugo AmatMultiwave Technologies, Marseille, France.ORCID https://orcid.org/0009-0005-1678-4764
Marc DuboisAix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.ORCID https://orcid.org/0000-0002-9195-7363
Aurelien DestruelAix Marseille Univ, CNRS, CRMBM, Marseille, France.ORCID https://orcid.org/0000-0002-7189-4764
Sajad HosseinnezhadianMultiwave Technologies, Marseille, France.ORCID https://orcid.org/0000-0002-6104-2138
Djamel BerrahouMultiwave Technologies, Marseille, France.
Charles BetempsAix Marseille Univ, CNRS, CRMBM, Marseille, France.
Amira TrabelsiMultiwave Technologies, Marseille, France.
David BendahanAix Marseille Univ, CNRS, CRMBM, Marseille, France.ORCID https://orcid.org/0000-0002-1502-0958
Stefan EnochAix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.ORCID https://orcid.org/0000-0003-0335-726X
Virginie CallotAix Marseille Univ, CNRS, CRMBM, Marseille, France.ORCID https://orcid.org/0000-0003-0850-1742
Redha AbdeddaimAix Marseille Univ, CNRS, Centrale Med, Institut Fresnel, Marseille, France.

Funding

Agence Nationale de la Recherche ANR-23-CE17-0019-01Amidex AMX-19-IET-002Amidex AMX-23-CI-01Amidex AMX-23-CPJ-10Amidex AMX-23-EQ-FO-009CNRS Ingenierie PEPS2024
6 · The paper itself

Abstract

purposeThe design of radiofrequency (RF) coils tailored for the target anatomy is necessary to overcome the transmit field homogeneity and penetration issues at Ultra-High-Field (UHF). For the spinal cord, the optimal design has not yet been determined. This work intends to demonstrate the added value of a pair of passive dipoles placed under a conventional thoracic spine 4 × 2-loop array.

methodsThe conventional loop array produces a broad transmit field with unnecessary lateral spread. To address this, two passive dipoles were incorporated and tuned out-of-phase to actively suppress these lateral side-lobes and increase field penetration the spinal cord region. The design was numerically optimised using a homogeneous phantom, followed by human voxel model simulations to evaluate performance and specific absorption rate (SAR). Finally, a prototype was tested in a 7T scanner using a homogeneous phantom to acquire experimental

resultsHuman voxel model simulations demonstrated that the passive dipoles improve the

conclusionIncorporating passive dipoles effectively suppresses unwanted lateral field spread, increasing penetration depth and

Indexed as

Magnetic Resonance ImagingSpinal CordThoracic VertebraeComputer SimulationEquipment DesignHumansImage Processing, Computer-AssistedPhantoms, ImagingRadio Waves7Tpassive dipolespassive shimmingradiofrequency coilspinal cordtransmit array

Identifiers

PMID42503837
PMCPMC13527284

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.