Evidence map›Paper›PMID 42503595›Full record

ArticleJournal of applied clinical medical physics2026

AI-assisted VMAT planning incorporating deep learning-based dose prediction for head and neck cancer: feasibility of quality standardization and human intervention for irregular cases.

Seiji Tomori, Kakutaro Narazaki, Shun Tasaka

Abstract read
In one paragraph

Article in Journal of applied clinical medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Seiji TomoriDepartment of Radiology, National Hospital Organization Sendai Medical Center, Sendai, Miyagi, Japan.
Kakutaro NarazakiDepartment of Radiology, National Hospital Organization Sendai Medical Center, Sendai, Miyagi, Japan.
Shun TasakaDepartment of Radiology, National Hospital Organization Sendai Medical Center, Sendai, Miyagi, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundVolumetric-modulated arc therapy (VMAT) represents a standard of care for head and neck cancer (HNC). However, treatment plan quality depends heavily on the planner's expertise, thereby challenging the standardization of treatment quality. While the clinical application of artificial intelligence (AI) in radiotherapy planning is rapidly increasing, the robustness of these models-for both typical and irregular cases-remains insufficiently understood. PURPOSE: To evaluate the clinical utility and generalizability of an artificial intelligence (AI)-assisted volumetric-modulated arc therapy (VMAT) planning workflow for head and neck cancer (HNC). This study focused on the robustness of AI-assisted planning using dose distribution prediction for various cases including complex anatomical variations, such as bulky tumors and irregular tumor ruptures, and explored the feasibility of quality standardization through a "human-in-the-loop" intervention approach via re-optimization. METHODS AND MATERIALS: Twelve VMAT plans from 11 HNC patients, including complex anatomical scenarios with bulky masses and post-rupture anatomical changes, were analyzed. Clinical plans developed by an experienced planner were compared with AI-assisted plans generated using RatoGuide (AiRato Inc.). The AI-assisted planning workflow utilized deep learning-based dose distribution prediction to generate dose-derived ring contours for optimization. A human-in-the-loop intervention was implemented, wherein planners performed manual fine-tuning if initial AI-assisted plans violated the institutional dose constraint of Dmax <115%. Dosimetric metrics for the planning target volume (PTV) and organs at risk (OARs), along with Paddick conformity index and monitor units (MU), were evaluated.

resultsAI-assisted plans achieved PTV coverage comparable to clinical plans while improving OAR sparing, particularly for the spinal cord and brainstem. The mean spinal cord PRV Dmax was reduced from 27.50 Gy in clinical plans to 23.97 Gy in AI-assisted plans. Even in cases with bulky or ruptured tumors, AI-assisted planning maintained high conformity and the overall mean Paddick conformity index was comparable to clinical plans. Although initial AI plans exhibited hotspots (Dmax > 115%) in three cases near the body surface, manual fine-tuning of optimization successfully suppressed these hotspots, meeting clinical criteria. AI-assisted planning maintained comparable mean MU values, and reduced the total planning time from approximately 2 h to 30 min.

conclusionThe AI-assisted planning workflow demonstrated the potential to produce high-quality VMAT plans, even for complex HNC cases. By integrating physicist human-in-the-loop intervention with AI efficiency, this approach could facilitate the standardization of radiotherapy treatment planning quality while supporting patient safety.

Indexed as

Artificial IntelligenceDeep LearningHead and Neck NeoplasmsQuality Assurance, Health CareRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedFeasibility StudiesHumansOrgans at RiskRadiotherapy Dosagedeep learningdose distribution predictionhead and neck cancerquality standardizationVMAT

Identifiers

PMID42503595
PMCPMC13402453

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.