Evidence map›Paper›PMID 42503571›Full record

ArticleJournal of robotic surgery2026

Clinical and radiographic outcomes of ROSA robotic-assisted total knee arthroplasty: a retrospective comparison of anatomic (persona) versus symmetric (vanguard) implant designs.

Murat Bozbek, Yunus Demirtaş, Özgür Kaya, Tahsin Aydın, Gökhan Çakmak, Ertuğrul Akşahin

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Murat BozbekDepartment of Orthopaedics and Traumatology, LIV Hospital Ankara, Ankara, Türkiye. drmuratbozbek@gmail.com.ORCID http://orcid.org/0009-0001-9283-2407
Yunus DemirtaşDepartment of Orthopaedics and Traumatology, LIV Hospital Ankara, Ankara, Türkiye.
Özgür KayaDepartment of Orthopaedics and Traumatology, LIV Hospital Ankara, Ankara, Türkiye.
Tahsin AydınDepartment of Orthopaedics and Traumatology, Ankara Bilkent City Hospital, Ankara, Türkiye.
Gökhan ÇakmakPrivate Practice, 1071 Usta Plaza, Kızılırmak, 1443. Cd. No:25 A Blok 5. Kat No:35, 06530 Çankaya, Ankara, Türkiye.
Ertuğrul AkşahinPrivate Practice, Söğütözü Cad. Koç Kuleleri , A Blok Kat: 8 No:27, Söğütözü, Çankaya, Ankara, Türkiye.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Whether an anatomic or a symmetric implant performs better when both are implanted on the same robotic platform remains unclear. We therefore compared short-term clinical and radiographic outcomes of the anatomic Persona and the symmetric Vanguard designs in ROSA robotic-assisted total knee arthroplasty (TKA). Sixty-four consecutive patients (33 Vanguard, 31 Persona), all receiving a posterior-stabilized bearing, were reviewed retrospectively at a single center with a minimum follow-up of 12 months. Outcome measures were the Oxford Knee Score (OKS), Knee Society Score (KSS), range of motion (ROM) assessed preoperatively and postoperatively, planned and achieved femoral (FC) and tibial (TC) component angles measured by ROSA before resection and at cut validation, hip-knee-ankle (HKA) alignment with a >3° outlier threshold, and operative time. OKS and KSS improved significantly from baseline in both groups (all p < 0.001), and the groups did not differ at 12 months (OKS p = 0.080; KSS p = 0.100). Preoperative ROM was comparable (flexion p = 0.81; extension deficit p = 0.73). Flexion was greater in the Persona group (122.2 ± 9.1° vs. 115.2 ± 7.7°; p < 0.001; d = 0.83) and the extension deficit smaller (6.2 ± 3.1° vs. 8.7 ± 2.6°; p = 0.001; d = 0.90). Postoperative HKA was similar (2.80 ± 0.59° vs. 2.65 ± 0.64°; p = 0.245); one Vanguard patient exceeded the 3° threshold, and no Persona patient did. Of the achieved component angles, FC coronal flexion (p = 0.028) and TC coronal varus (p = 0.018) differed between groups. With both implants, ROSA-assisted TKA achieved equivalent HKA alignment within the range reported for the platform and excellent, comparable patient-reported outcomes. Small implant-specific differences remained in the achieved component angles. The Persona design was also associated with a range-of-motion advantage with large effect sizes, a finding specific to this retrospective cohort. These early findings should be tested in larger randomized trials with longer follow-up. Level of Evidence. III (retrospective cohort study).

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisProsthesis DesignRobotic Surgical ProceduresAgedFemaleHumansKnee JointMaleMiddle AgedRadiographyRange of Motion, ArticularRetrospective StudiesTreatment OutcomeAccuracyPersona knee systemRobotic-assisted surgeryROSATotal knee arthroplasty

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.