Evidence map›Paper›PMID 42502900›Full record

ArticleMagnetic resonance in medicine2026

In Vivo Measurement of Taurine With Optimized Double-Quantum Filtering Magnetic Resonance Spectroscopy.

Yufan Zhou, Chenting Ye, Jiaqiang Zhou, Yang Cao, Dingyi Lin, Yefeng Yao, Hong Zhang, Min Wang

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Yufan ZhouKey Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Chenting YeKey Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Jiaqiang ZhouDepartment of Endocrinology, School of Medicine, Sir Run Run Shaw Hospital, Zhejiang University, Hangzhou, Zhejiang, China.
Yang CaoKey Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Dingyi LinKey Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Yefeng YaoInstitute of Medical Magnetic Resonance and Molecular Imaging Technology, East China Normal University, Shanghai, China.ORCID https://orcid.org/0000-0002-6274-2048
Hong ZhangKey Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.
Min WangKey Laboratory for Biomedical Engineering of Ministry of Education, College of Biomedical Engineering and Instrument Science, Zhejiang University, Hangzhou, Zhejiang, China.ORCID https://orcid.org/0000-0002-1072-5983

Funding

National Key Research and Development Program of China 2021YFA1101700National Natural Science Foundation of China 32301159National Natural Science Foundation of China 82572290Zhejiang Provincial Natural Science Foundation of China LZ25H180002
6 · The paper itself

Abstract

purposeTo enhance the accuracy and reproducibility for in vivo taurine quantification using the double-quantum filtering (DQF) technique.

methodsSimulations and phantom experiments were conducted at both 7 T and 3 T to determine the optimal parameter τ by calculating the taurine purity index among other neighboring metabolites. The frequency-selective read-pulse bandwidth and the dephasing/rephasing gradient moments were further adjusted to reduce residual water side band interference. Rat models of C6 gliomas were compared to normal brain for taurine level at 7 T. Metabolomics was conducted to validate the accuracy of taurine quantification. Human gray and white matter taurine differences were revealed at 3 T. Test-retest reliability was evaluated on humans.

resultsSimulations and phantom experiments identified optimal τ for maximizing taurine signal purity as 102 ms at 7 T and 92 ms at 3 T. The best combinations of parameters for minimal water interference were determined at 3 T. Optimized DQF sequences yielded lower CRLBs. In rat brains, taurine concentration measured with optimized DQF sequences exhibited strong correlation with metabolomics, outperforming both conventional MRS and nonoptimized DQF sequences. Only the optimized method revealed significant taurine concentration differences between gray and white matter. Test-retest demonstrated good reproducibility in gray matter (ICC = 0.82) for the optimized method.

conclusionThe optimized DQF method enhances taurine detection accuracy and robustness in both animal and human studies and was for the first time applied in human brain taurine test at 3 T.

Indexed as

TaurineAlgorithmsAnimalsBrainBrain NeoplasmsComputer SimulationGliomaGray MatterHumansMagnetic Resonance SpectroscopyMaleMetabolomicsPhantoms, ImagingRatsReproducibility of ResultsWhite MatterTaurinedouble‐quantum filteringgray matterneurochemicalspectral editingtaurinewhite matter

Identifiers

PMID42502900
PMCPMC13527257

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.