Evidence map›Paper›PMID 42502729›Full record

ArticleJHLT open2026

Handheld infrared thermography for triage of LVAD driveline infection: A prospective pilot diagnostic accuracy study.

Theofanis Mavrepis, Stijn Legtenberg, Peter van der Meer, Michiel Kuijpers, Yvonne Douglas, Michiel E Erasmus, Jozine M Ter Maaten, Stan A J van den Broek, Jan A Krikken, Kevin Damman

Abstract read
In one paragraph

Article in JHLT open, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Theofanis MavrepisUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Stijn LegtenbergUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Peter van der MeerUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Michiel KuijpersUniversity of Groningen, Departement of Cardiothoracic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Yvonne DouglasUniversity of Groningen, Departement of Cardiothoracic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Michiel E ErasmusUniversity of Groningen, Departement of Cardiothoracic Surgery, University Medical Center Groningen, Groningen, The Netherlands.
Jozine M Ter MaatenUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Stan A J van den BroekUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Jan A KrikkenUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.
Kevin DammanUniversity of Groningen, Departement of Cardiology, University Medical Center Groningen, Groningen, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Existing approaches to diagnose driveline infections (DLI) in patients with durable left ventricular assist devices (LVADs) differ in speed, cost, and specificity. Handheld infrared thermography may support DLI through rapid, easy, non-contact triage by detecting local temperature elevation. Methods: In this prospective, single-center diagnostic accuracy study, adult LVAD patients underwent handheld thermal imaging of the driveline exit site. Performance of thermography in predicting clinically diagnosed DLI was assessed using receiver operating characteristic analysis (AUC with 95% confidence intervals [CI], DeLong). The threshold derived using Youden's J was considered exploratory and intended for internal within-study performance estimation only; sensitivity, specificity, PPV, and NPV were calculated with exact (Clopper-Pearson) 95% CIs. Associations were assessed using logistic regression and Firth's penalized logistic regression; correlation with high-sensitivity C-reactive protein was assessed using Spearman's ρ. Results: Fifty patient episodes were analyzed, of which 6 (12%) had DLI. Median peri-driveline temperature was higher in patients with DLI than without DLI (36.1°C vs 34.4°C; Conclusions: Handheld infrared thermography showed good discrimination for DLI, and no false negatives were observed at a low threshold, albeit with limited specificity. These findings support further evaluation as a triage adjunct rather than a stand-alone diagnostic test.

Indexed as

Diagnostic accuracyDriveline infectionInfrared thermographyLeft ventricular assist deviceTriage

Identifiers

PMID42502729
PMCPMC13401013

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.