Evidence map›Paper›PMID 42500699›Full record

ArticleActa ortopedica brasileira2026

VALIDATION OF AN OPTICAL METHOD FOR MEASURING THE GAP BETWEEN SUTURED TENDON STUMPS.

Luiz Sorrenti, Elcio Koodiro Yoshida, Antonio Isidoro de Sousa, César Augusto Martins Pereira, Hugo Alberto Nakamoto, Rames Mattar

Abstract read
In one paragraph

Article in Acta ortopedica brasileira, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Luiz SorrentiUniversidade de Sao Paulo, Faculdade de Medicina, Hospital das Clinicas, (HC-FMUSP), Instituto de Ortopedia e Traumatologia, Hand Surgery and Reconstructive Microsurgery Group, Sao Paulo, SP, Brazil.ORCID https://orcid.org/0000-0003-1160-8559
Elcio Koodiro YoshidaUniversidade de Sao Paulo, Faculdade de Medicina, Hospital das Clinicas, (HC-FMUSP), Instituto de Ortopedia e Traumatologia, Hand Surgery and Reconstructive Microsurgery Group, Sao Paulo, SP, Brazil.ORCID https://orcid.org/0009-0005-4798-3352
Antonio Isidoro de SousaUniversidade de Sao Paulo, Faculdade de Medicina, Hospital das Clinicas, (HC-FMUSP), Instituto de Ortopedia e Traumatologia, Hand Surgery and Reconstructive Microsurgery Group, Sao Paulo, SP, Brazil.ORCID https://orcid.org/0009-0005-5522-8402
César Augusto Martins PereiraUniversidade de Sao Paulo, Faculdade de Medicina, Hospital das Clinicas, (HC-FMUSP), Instituto de Ortopedia e Traumatologia, Hand Surgery and Reconstructive Microsurgery Group, Sao Paulo, SP, Brazil.ORCID https://orcid.org/0000-0002-9867-397X
Hugo Alberto NakamotoUniversidade de Sao Paulo, Faculdade de Medicina, Hospital das Clinicas, (HC-FMUSP), Instituto de Ortopedia e Traumatologia, Hand Surgery and Reconstructive Microsurgery Group, Sao Paulo, SP, Brazil.ORCID https://orcid.org/0000-0002-7301-4329
Rames MattarUniversidade de Sao Paulo, Faculdade de Medicina, Hospital das Clinicas, (HC-FMUSP), Instituto de Ortopedia e Traumatologia, Hand Surgery and Reconstructive Microsurgery Group, Sao Paulo, SP, Brazil.ORCID https://orcid.org/0000-0003-4202-4652

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: This study aims to investigate the accuracy and precision of an optical measurement method based on backlight video analysis for measuring gap distances between tendon stumps in a rigid tendon model. Methods: A rigid 3D-printed tendon model was sutured and subjected to traction using a universal mechanical testing machine. The gap between stumps was filmed in frontal and lateral planes with backlight illumination and a simple mirror system. A custom software program calculated gap distances from the recorded videos and the optical measurements were compared with mechanical testing machine measurements to assess precision and accuracy. Results: The mean difference (bias) in the frontal plane was -0.01 mm (SD: 0.01 mm) and in the lateral plane was 0.04 mm (SD: 0.03 mm). Bland-Altman analysis showed limits of agreement (LoA) of 0.04 mm in the frontal plane and 0.06 mm in the lateral plane. Measurements between planes showed a very strong correlation with a Spearman's rho correlation test of 1.000 (p<0.001). Conclusion: The optical method showed errors on the order of hundredths of a millimeter and proved to be both precise and accurate, validating a new method for gap measurement in biomechanical tendon studies.

Indexed as

Biomechanical PhenomenaSuture TechniquesTendonsTendon Transfer

Identifiers

PMID42500699
PMCPMC13399199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.