Evidence map›Paper›PMID 42500488›Full record

ArticleFrontiers in bioengineering and biotechnology2026

A novel internal fixation system for sacral fractures: a finite element biomechanical study.

Bin Chen, Xinbo Gu, Beiyang Wang, Ningning Shen, Mingming Kang, Bo Zhang, Haiyu Sun, Huan Wang, Yonghong Zhang

Abstract read
In one paragraph

Article in Frontiers in bioengineering and biotechnology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Bin Chen *Second Clinical Medical College, Shanxi Medical University, Taiyuan, China.
Xinbo Gu *Second Clinical Medical College, Shanxi Medical University, Taiyuan, China.
Beiyang Wang *Third Hospital of Shanxi Medical University, Shanxi Bethune Hospital, Shanxi Academy of Medical Sciences, Tongji Shanxi Hospital, Taiyuan, China.
Ningning ShenSecond Clinical Medical College, Shanxi Medical University, Taiyuan, China.
Mingming KangSecond Clinical Medical College, Shanxi Medical University, Taiyuan, China.
Bo ZhangSecond Clinical Medical College, Shanxi Medical University, Taiyuan, China.
Haiyu SunDepartment of Orthopaedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Huan WangDepartment of Orthopaedics, Second Hospital of Shanxi Medical University, Taiyuan, China.
Yonghong ZhangDepartment of Orthopaedics, Second Hospital of Shanxi Medical University, Taiyuan, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Sacroiliac joint screw (SIJS) fixation is widely regarded as the gold standard for treating unstable posterior pelvic ring injuries. However, the technique presents notable challenges, including a high risk of neurovascular injury and a steep learning curve. This study aimed to introduce a novel Posterior Internal Fixation (P-INFIX) system and evaluate its biomechanical performance in the treatment of Denis zone I sacral fractures using finite element analysis. Methods: A three-dimensional pelvic model-cortical bone, cancellous bone, and cartilage-was reconstructed from computed tomography data of a healthy volunteer. A Denis zone I sacral fracture was simulated and stabilized using either the P-INFIX system (bilateral pedicle screws connected by a transverse Kirschner wire) or the standard SIJS. Finite element analysis was conducted under simulated sitting, supine, and lateral decubitus conditions to assess fracture fragment displacement and implant stress distribution. Results: The P-INFIX system provided fracture stability comparable to SIJS under most testing conditions. Although SIJS demonstrated a slight statistical advantage in limiting lateral fragment displacement (For example, Z2 in the sitting position: 0.13 mm vs. 0.18 mm, Conclusion: The novel P-INFIX system demonstrated biomechanical stability comparable to the gold standard SIJS in managing Denis zone I sacral fractures. Given its potential to reduce surgical risks and simplify the procedure through a "safe channel" lateral to the posterior superior iliac spine, P-INFIX represents a promising and more accessible alternative fixation technique.

Indexed as

biomechanicsfinite element analysisinternal fixationnovel fixation systemposterior pelvic ringsacral fractures

Identifiers

PMID42500488
PMCPMC13395768

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.