Evidence map›Paper›PMID 42500307›Full record

ArticleResuscitation plus2026

Optimizing automated external defibrillator incremental deployment to improve out-of-hospital cardiac arrest coverage: a spatial optimization study.

Pengfei Cheng, Ding Luo, Hua Zhang, Baichao Xu, Pengyu Yang, Huachen Xue, Xiaobing Zhai, Ying Xiao

Abstract read
In one paragraph

Article in Resuscitation plus, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Pengfei ChengFaculty of Medicine, Macau University of Science and Technology, Taipa, Macau.
Ding LuoCollege of Nursing, the 1st and 2nd Affiliated Hospital, Key Laboratory of Emergency and Trauma, Ministry of Education, Hainan Medical University, Haikou, Hainan, China.
Hua ZhangInternational Nursing School, Hainan Medical University, Haikou, Hainan, China.
Baichao XuDepartment of Physical Education, Hainan Medical University, Haikou, Hainan, China.
Pengyu YangDepartment of Nursing Science, Faculty of Medicine, Universiti Malaya, Kuala Lumpur, Wilayah Persekutuan, Malaysia.
Huachen XueFaculty of Medicine, Macau University of Science and Technology, Taipa, Macau.
Xiaobing ZhaiFaculty of Applied Sciences, Macao Polytechnic University, Macau.
Ying XiaoFaculty of Medicine, Macau University of Science and Technology, Taipa, Macau.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Public access defibrillation (PAD) is critical for out-of-hospital cardiac arrest (OHCA) response, yet the effectiveness of existing automated external defibrillator (AED) networks remains limited in many urban settings. Evidence is lacking on how incremental AED deployment translates into coverage gains and when diminishing returns occur, particularly in resource-constrained cities. Methods: A retrospective spatial analysis was conducted using Utstein-compliant OHCA registry data from Haikou City, China (2015-2021). AED coverage was assessed using Euclidean distance across response radii of 100-500 m. Incremental AED deployment was simulated using the maximal covering location problem (MCLP) model while holding the existing network fixed. Changes in coverage, marginal gains, saturation thresholds, and optimized location types were evaluated using geographic information system methods. Results: Among 5792 eligible OHCA events, baseline AED coverage was limited (14.6% within 100 m; 45.7% within 500 m). Incremental deployment produced rapid early coverage gains across all distance thresholds, followed by diminishing marginal returns and eventual saturation. Near-saturation required substantially more AEDs at shorter radii (approximately 1467 additional devices at 100 m) compared with larger radii (308-499 devices at 300-500 m). Optimized deployment shifted priority toward restaurants and commercial/industrial settings, while home or private residence, transportation hubs, and government/educational institution yielded lower marginal gains despite hosting most existing AEDs. Conclusions: Existing AED networks provide limited OHCA coverage due to spatial mismatch between placement and demand. MCLP-guided deployment shows early gains but diminishing returns, supporting phased, locally-calibrated expansion that maximizes effective emergency access, especially in resource-constrained settings.

Indexed as

Automated external defibrillatorMaximal covering location problemOut-of-hospital cardiac arrestPublic access defibrillation

Identifiers

PMID42500307
PMCPMC13396928

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.