ArticleDose-response : a publication of International Hormesis Society
Dose Reconstruction After a WD‒XRF Spectrometer Accident Using Minute-Rate TLD Measurements.
Article in Dose-response : a publication of International Hormesis Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Accurate dose estimation following radiation accidents remains challenging, particularly when personal dosimeter data are unavailable. This study presents a practical post-accident dose reconstruction approach based on minute-rate thermoluminescent dosimeter (TLD) measurements combined with exposure scenario reconstruction, demonstrated through a wavelength-dispersive X-ray fluorescence (WD‒XRF) spectrometer accident. The exposure scenario was reconstructed by placing LiF(Mg,Cu,P) TLDs at seven representative positions corresponding to head and hand locations, with the spectrometer operated under the recorded technical parameters (40 kV, 7 mA). Minute personal dose equivalent rates,
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.