ArticleMedical physics2026

A Comparative dose and image quality assessment of a portable, multi-modality extremity imaging system for austere environments.

Xiangyu Yang, Edward J Stafford, Hadley A DeBrosse, Yi Wei, Adam Smith, David E Hintenlang, Nathaniel Bates

Abstract readComparative Study
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Xiangyu YangDepartment of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Edward J StaffordDepartment of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Hadley A DeBrosseDepartment of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Yi WeiDepartment of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Adam SmithDepartment of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
David E HintenlangDepartment of Radiology, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.
Nathaniel BatesDepartment of Orthopaedics, The Ohio State University Wexner Medical Center, Columbus, Ohio, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRapid technological innovation in diagnostic imaging requires timely, evidence-based safety and quality assessment to ensure optimal patient care. This study evaluates a novel multi-modality extremity imaging system (OXOS MC2) designed for deployment in remote and austere environments. PURPOSE: To systematically evaluate the radiation safety and image quality characteristics of the MC2 system in its three imaging modalities (radiography, fluoroscopy, and Dynamic Digital Radiography [DDR]), and to compare them with two conventional, single-modality reference systems: a portable radiographic unit and a mobile C-arm fluoroscopic unit.

methodRadiation dose and image quality were assessed for four extremity regions (hand, shoulder, ankle, knee). Patient dose metrics (Entrance Air Kerma [EAK] and Entrance Air Kerma Rate [EAKR]) were estimated using clinical techniques and measured primary radiation output. Operator dose (effective dose equivalent, H

resultsThe MC2 system demonstrated substantially lower patient EAK compared to the radiographic reference system (14%-59% of the reference). Although EAKR varied relative to the reference fluoroscopic system (15%-245% of the reference) due to differences in setup, the MC2's maximum AKR (3.53 mGy/min) remained well below the regulatory limit (44 mGy/min), indicating a negligible risk of radiation-induced skin injury for the patient. The IRID and IDRIR exhibited trends similar to the EAK and EAKR. Operator doses for the MC2 were consistently lower than those of both reference systems, with the H

conclusionThe OXOS MC2 is a safe and versatile imaging system capable of meeting various extremity imaging needs in remote and austere environments. With substantially reduced radiation dose and improved portability, it provides a robust alternative to conventional portable radiographic systems. While the MC2 system exhibits compromises in spatial resolution and beam hardness, its unique multi-modality capabilities enable the field deployment of previously inaccessible fluoroscopic and DDR imaging, thereby greatly enhancing patient access to advanced imaging techniques in resource-limited settings.

Indexed as

ExtremitiesMultimodal ImagingRadiation DosageFluoroscopyHumansPhantoms, ImagingQuality ControlRadiographic Image EnhancementDDRfield imagingportable radiography

Identifiers

PMID42499286
PMCPMC13401090

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.