Evidence map›Paper›PMID 42496618›Full record

ArticleJACC. Asia2026

Transcatheter Edge-to-Edge Repair for Tricuspid Regurgitation: Design and Rationale of the TEER-CHINA Trial.

Kaida Ren, Boren Tan, Xinping Lin, Zhaoxia Pu, Lihan Wang, Po Hu, Jubo Jiang, QiFeng Zhu, Jiaqi Fan, Yuxin He and 8 more

Registry-linked trialAbstract read
In one paragraph

Article in JACC. Asia, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT05556460 (A Prospective, Multicenter, Parallel, Randomized Controlled Study to Evaluate the Safety and Effectiveness of the DragonFly-T Transcatheter Tricuspid Valve Clip System in the Treatment of Tricuspid Regurgitation), which is not on this map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT05556460 narecruitingnot on this map

A Prospective, Multicenter, Parallel, Randomized Controlled Study to Evaluate the Safety and Effectiveness of the DragonFly-T Transcatheter Tricuspid Valve Clip System in the Treatment of Tricuspid Regurgitation

TypeinterventionalSponsorHangzhou Valgen Medtech Co., LtdRan2024 to 2032Enrolled236ConditionsTricuspid RegurgitationArmsDragonFly-T Transcatheter Tricuspid Valve Repair System, Medical therapy
3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

18 authors.

Kaida RenDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Boren TanDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Xinping LinDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Zhaoxia PuDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Lihan WangDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Po HuDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Jubo JiangDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
QiFeng ZhuDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Jiaqi FanDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Yuxin HeDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Yuchao GuoDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Qiong LiuDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Jie LiangDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Huajun LiDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Huixiang YanDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Haochang HuDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China.
Xianbao LiuDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China; Transvascular Implant Instrument Research Institute, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, Zhejiang, China; Binjiang Institute of Zhejiang University, Hangzhou, China. Electronic address: liuxb@zju.edu.cn.
Jian'an WangDepartment of Cardiology, The Second Affiliated Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China; State Key Laboratory of Transvascular Implantation Devices, Hangzhou, Zhejiang, China; Heart Regeneration and Repair Key Laboratory of Zhejiang province, Hangzhou, Zhejiang, China; Transvascular Implant Instrument Research Institute, The Second Affiliated Hospital Zhejiang University School of Medicine, Hangzhou, Zhejiang, China; Binjiang Institute of Zhejiang University, Hangzhou, China. Electronic address: wangjianan111@zju.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTricuspid regurgitation (TR) is common, and severe TR independently predicts mortality and heart failure hospitalization, leading to functional impairment and poor quality of life. Optimal medical therapy (OMT), mainly using diuretic agents, provides symptomatic relief but does not correct valvular dysfunction and is often limited by the resistance of diuretic agents. Isolated tricuspid valve surgery remains high risk. Transcatheter options have therefore emerged, with transcatheter edge-to-edge repair (TEER) widely adopted.

objectivesThe Transcatheter Edge-to-Edge Repair for Tricuspid Regurgitation in China (TEER-CHINA) study is designed to evaluate the safety and efficacy of the DragonFly-T System compared with OMT in patients with severe TR.

methodsThe TEER-CHINA trial is a prospective, multicenter, randomized controlled trial (NCT05556460) in which a total of 236 participants will be enrolled across 35 centers in China and randomized 1:1 to the device group or OMT alone. Key inclusion criteria include patients with severe or greater TR (≥3+) who remain clinically symptomatic despite OMT for at least 30 days, are at intermediate or higher surgical risk for tricuspid valve surgery by the local Heart Team, and are anatomically suitable for use of the investigational device. Participants will be followed up at 30 days, 6 months, 12 months, and annually thereafter for up to 5 years.

resultsThe primary endpoint is a hierarchical composite assessed at 12 months, including all-cause mortality or tricuspid valve intervention, annualized heart failure hospitalization rates, and improvement in health status measured by the Kansas City Cardiomyopathy Questionnaire.

conclusionsThe TEER-CHINA trial is designed to assess the efficacy and safety of the DragonFly-T System and to inform future treatment strategies for severe TR.

Indexed as

DragonFly-Trandomized controlled trialtranscatheter edge-to-edge repairtricuspid regurgitation

Identifiers

PMID42496618
PMCPMC13554751

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.