Evidence map›Paper›PMID 42495782›Full record

ArticleActa oncologica (Stockholm, Sweden)2026

Dose calculation errors for volumetric modulated arc therapy plans of various complexity.

Emmanouil Terzidis, Fredrik Nordström, Magnus Gustafsson, Anna Karlsson, Julia Götstedt, Anna Bäck

Abstract read
In one paragraph

Article in Acta oncologica (Stockholm, Sweden), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Emmanouil TerzidisDepartment of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Therapeutic Radiation Physics, Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden. emmanouil.terzidis@gu.se.ORCID 0000-0002-3229-6761
Fredrik NordströmDepartment of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Therapeutic Radiation Physics, Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden.ORCID 0000-0003-2898-5676
Magnus GustafssonDepartment of Therapeutic Radiation Physics, Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden.
Anna KarlssonDepartment of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Therapeutic Radiation Physics, Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden.
Julia GötstedtDepartment of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Therapeutic Radiation Physics, Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden.ORCID 0000-0002-7363-347X
Anna BäckDepartment of Medical Radiation Sciences, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg; Department of Therapeutic Radiation Physics, Biomedical Engineering and Medical Physics, Sahlgrenska University Hospital, Gothenburg, Sweden.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeVolumetric modulated arc therapy (VMAT) plans often involve small and irregular beam apertures (i.e. high complexity), which can pose challenges for accurate dose calculations. The aim of this study was to investigate plausible dose calculation errors for VMAT plans of various complexity. Patient/material and methods: Twenty patient cases, each with three VMAT plans of different complexities (i.e. 60 plans in total), were included. All plans were calculated using six different dose calculation methods. It was assumed that greater differences between calculations reflect increased difficulty in accurately estimating dose. Basic performances of the six calculation methods were evaluated based on static fields. Three-dimensional distributions of voxel-wise two standard deviations (2SDs) in percent of local voxel dose were visually evaluated. 2SD volume histograms were analyzed as well as the mean (2SDMean) and maximum 2SD within 2 cm3 (2SD2cc) for different regions of interest.

resultsHigher 2SD values were generally found outside the planning target volume (PTV) compared to inside, particularly in low dose and buildup regions. Average (per treatment site) 2SDMean/2SD2cc values were 0.9-1.2%/1.8-5.1% in the PTV and 1.8-3.1/8.4-18.7% for the region 1 cm outside the PTV. For organs of interest, 2SDMean/2SD2cc values were larger than the equivalent values in the PTV, with highest values up to 5/15% observed for the prostate cases.

interpretationVariations between dose calculation methods were larger in organs of interest than in the PTVs. Differences in 2SD distributions between the patient cases were generally larger than differences between the complexity levels.

Indexed as

Prostatic NeoplasmsRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedHumansMaleOrgans at RiskRadiotherapy Dosage

Identifiers

PMID42495782
PMCPMC13410304

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.