Dosimetric evaluation of patient-side range shifters using two materials for superficial region treatment in spot scanning proton therapy: impact of material, air gap and setup distance.

Seiichi Ota, Tomohiro Kajikawa, Toshiyuki Ogata, Hisashi Takaya, Kenta Kijima, Tetsuya Okita, Norihiro Aibe

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of radiation research, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Seiichi OtaDivision of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.ORCID 0000-0002-0133-397X
Tomohiro KajikawaDepartment of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
Toshiyuki OgataDepartment of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
Hisashi TakayaDivision of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
Kenta KijimaDivision of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
Tetsuya OkitaDivision of Radiological Technology, Department of Medical Technology, University Hospital, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.
Norihiro AibeDepartment of Radiology, Kyoto Prefectural University of Medicine, 465 Kajii-cho, Kawaramachi-Hirokoji, Kamigyo-ku, Kyoto 602-8566, Japan.ORCID 0000-0002-6595-0205

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study aimed to evaluate the dosimetric characteristics of patient-side range shifters (RS) made of polymethyl methacrylate and high-density polyethylene for superficial region treatment in spot scanning proton therapy. The impact of air gap (AG) size and RS setup deviations on dose accuracy was investigated. A virtual water phantom and a simple volumetric beam arrangement were used for dose calculations in a treatment planning system employing a pencil beam algorithm with a triple Gaussian kernel. Gamma passing rates (GPRs) and point dose measurements were performed using a two-dimensional detector array and an ionization chamber, with AGs ranging from 0 to 110 mm. Results showed that GPRs exceeded 90% at depths of 9, 20 and 50 mm when the AG was within 80 mm, even under 2%/2 mm evaluation criteria. At AGs of 90-110 mm, reduced GPRs and >3% deviations in point dose measurements were observed at shallow depths. Setup deviation experiments were conducted by intentionally shifting the RS slab from the geometry used for reference measurements, and GPRs were evaluated relative to the corresponding measured reference at each original AG. The results indicated that shifts of up to ±10 mm from the reference AG had minimal dosimetric impact, with GPRs remaining above 96.8% under 1%/1 mm criteria. Maintaining the AG within 80 mm is recommended to ensure dosimetric accuracy. These findings suggest that patient-side RS systems can be a practical option in clinical scenarios where nozzle-mounted RS devices are not feasible.

Indexed as

PolyethylenePolymethyl MethacrylateProton TherapyRadiometryAirHumansPhantoms, ImagingRadiotherapy DosageRadiotherapy Planning, Computer-AssistedReproducibility of ResultsPolyethylenePolymethyl Methacrylateair gapimmobilizationproton therapyrange shifterspot scanningsuperficial target

Identifiers

PMID42490513

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.