Evidence map›Paper›PMID 42489823›Full record

ArticlePhysical and engineering sciences in medicine2026

From point sources to phantoms: refining dose rate models in nuclear medicine with Tc-99m, F-18, I-131 and Lu-177.

Joshua Ierace, Pejman Rowshanfarzad, Christine Sinnott, Rikki Nezich, Paul Brayshaw, Mario Djukelic

Abstract read
In one paragraph

Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Joshua IeraceSchool of Physics, Mathematics and Computing, University of Western Australia, Crawley, WA, Australia. joshuaierace@gmail.com.ORCID https://orcid.org/0009-0002-3738-6384
Pejman RowshanfarzadSchool of Physics, Mathematics and Computing, University of Western Australia, Crawley, WA, Australia.ORCID http://orcid.org/0000-0001-8306-7742
Christine SinnottDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.ORCID http://orcid.org/0000-0002-9572-4065
Rikki NezichDepartment of Medical Technology and Physics, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.ORCID http://orcid.org/0000-0002-1473-1379
Paul BrayshawDepartment of Nuclear Medicine and WA PET Centre, Sir Charles Gairdner Hospital, Nedlands, WA, Australia.
Mario DjukelicGenesisCare WA, 24 Salvado Rd, Wembley, WA, 6014, Australia.ORCID http://orcid.org/0000-0003-2221-5566

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Healthcare workers are often exposed to external radiation from patients who have been administered radionuclides for nuclear medicine (NM) studies, particularly during subsequent procedures requiring close contact. Traditional dose rate estimates commonly assume patients to be unattenuated point sources and apply inverse square law calculations, which tend to overestimate exposures at clinical distances. This study presents an experimental approach to quantify dose rates more accurately from NM patients using point, line, and phantom source models of Tc-99m, F-18, I-131, and Lu-177. Measurements were performed with calibrated ionisation chambers under controlled low-background conditions. Radionuclide activities were selected to achieve detectable dose rates while minimising staff exposure. Point and line source measurements provided baseline external exposure data across 10-100 cm. Phantom models, including a homogeneous water-filled NEMA body phantom and a PMMA neck phantom, were used to replicate clinical patient geometries. Dose rates were decay-corrected, normalised to activity, and fitted with biexponential models to generate exposure curves. Gamma factors (GFs) were evaluated at 0.3 m and 1.0 m from the centre of the radioactive source and compared with internationally recognised literature values. Self-absorption factors (SFs) were derived by comparing phantom and point source curves across clinical distances. Measured GFs showed excellent agreement with published data and internationally recognised standards, differing by only 2% for F-18 at both 30 cm (1.84 μSv/h/MBq) and 100 cm (0.161 μSv/h/MBq), and by 1% for I-131 at 30 cm (0.721 μSv/h/MBq). The average SF for F-18 (0.71 ± 0.04), representing patient self-attenuation for an unknown body orientation, was consistent with published Monte Carlo estimates. Differences reported in the literature were attributed to methodological variations, including the use of computational modelling rather than direct experimental measurements, along with variations in phantom design, source geometry, and detector configuration. This work presents an experimentally measured dataset with corresponding dose rate models for NM applications. The results contribute additional empirical evidence that may be used alongside established radiation protection methodologies to support assessments of shielding, procedure scheduling, and occupational and public radiation risk, potentially reducing reliance on overly conservative assumptions when evaluating dose rates at clinical distances.

Indexed as

Iodine RadioisotopesLutetiumNuclear MedicinePhantoms, ImagingRadiation DosageRadioisotopesTechnetiumHumansIodine-131Iodine RadioisotopesLutetiumLutetium-177RadioisotopesTechnetiumDose rate measurementGamma factorNuclear medicineRadiation protectionSelf-absorption factorTheranostics

Identifiers

PMID42489823
PMCPMC13638693

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.