ArticleThe Iowa orthopaedic journal2026
Biomechanical Evaluation of Suture Tape Versus Metallic Wire With Cannulated Screws Tension Band Fixation For Transverse Patella Fractures: A Biomechanical Study.
Article in The Iowa orthopaedic journal, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Transverse patella fractures requiring surgical fixation are typically treated with a tension band construct using metal wire. This technique is associated with high rates of complications and reoperation. Alternative fixation technique utilizing non-absorbable suture materials have been introduced. This biomechanical study aims to compare the stability of two tension band constructs, both utilizing headed cannulated lag screws, with either suture tape or traditional metal wire under cyclic load conditions, simulating repetitive physiological stress. Methods: Six matched pairs of fresh frozen cadaveric knees were obtained for testing. A standardized transverse patellar osteotomy (AO/OTA 34C1.1) was created in each to simulate a simple transverse patella fracture. Each pair was repaired using a tension band construct with headed cannulated screws, randomized to fixation with either suture tape or metal wire. All specimens underwent cyclic loading from 0 to 90 knee flexion at a frequency of 0.2 Hz for up to 1000 cycles. Two displacement transducers were used to measure real-time fracture gap displacement during testing from the start of testing and until clinical fixation failure. Clinical failure is defined as fracture gap displacement > 3 mm. Results: Clinical failure occurred in 5 of 6 specimens (83%) in the suture tape group, with a mean of 296±433 cycles. In the metal wire group, 4 of 6 specimens (67%) experienced clinical failure, with a mean of 421±461 cycles. There was no statistically significant difference in cycles to failure between the two groups (p=0.29). Kaplan-Meier survival analysis demonstrated a 500-cycle survival rate of 33% (95% CI: 0%-71%) for both groups. Conclusion: Both constructs may be considered viable options for the surgical treatment of simple transverse patella fractures. Level of Evidence: V.
Indexed as
Identifiers
42488310PMC13389598What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.