ArticleHeart rhythm O22026
Indication and electrical performance of conventional, resynchronization, and conduction system pacing in transthyretin amyloid cardiomyopathy.
Article in Heart rhythm O2, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04776824 (Swiss Cardiac Amyloidosis REgistry), which is not on this map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Swiss Cardiac Amyloidosis REgistry (Swiss-CARE)
Who cites it
1 citing paper in PubMed.
- Marching to a new beat: Choosing the right pacing strategy in transthyretin cardiac amyloidosis.Heart rhythm O2 · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background: Conduction system disorders and arrhythmias may require pacemaker (PM) or implantable cardioverter-defibrillator implantation in transthyretin amyloid cardiomyopathy (ATTR-CM). The optimal mode of pacing in ATTR-CM remains unknown. Objective: This study aimed to compare the electrical performance and clinical outcomes of conventional, resynchronization, and conduction system pacing (CSP) in ATTR-CM. Methods: In this observational study, the effects of cardiac pacing were investigated in 250 consecutive patients with ATTR-CM presenting at Inselspital Bern between June 2019 and February 2023. Results: During follow-up, 67 of 250 patients (26.8%) received a PM. Implantation of conventional single- (VVI) or dual-chamber (DDD) PMs was more common before ATTR-CM diagnosis (n = 17 of 25; 68%), and physiological pacing (cardiac resynchronization therapy [CRT]/CSP) was increasingly used thereafter (n = 24 of 42 [57.1%]). Sick sinus syndrome (n = 11 of 35 [31.4%] vs 6 of 32 [18.8%]) and higher-degree atrioventricular block (n = 20 of 35 [57.1%] vs 9 of 32 [28.1%]) were more common indications for VVI/DDD, with pursuit of a pace/ablate strategy (n = 12 of 32 [37.5%]) and heart failure (HF) (n = 5 of 32 [15.6%]) contributing significantly to implantation of CRT/CSP. QRS duration width was significantly lower with CSP (122 ms [interquartile range {IQR} 120-139]) than CRT (155 ms [IQR 141-160]) or VVI/DDD (160 ms [IQR 144-180]; Conclusion: Offering stable electrical performance and improved resynchronization, the effect of CSP on clinical outcomes warrants further exploration in ATTR-CM.ClinicalTrials.gov identifier: NCT04776824.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.