ArticlePloS one2026
Low-latency stage-adaptive cascade architecture for real time non-stationary noise filtering.
Article in PloS one, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
In many real-time measurement and monitoring systems, the quality of acquired signals is often severely degraded by complex environmental noise sources with non-stationary properties, rendering analysis, important feature extraction, and decision-making unreliable. This study proposes a multi-stage adaptive denoising architecture based on the least mean square (LMS) algorithm, in which the number of filter stages and the step size are automatically adjusted according to error statistics, the remaining correlation between the residual and the reference signal, and the real-time signal-to-noise ratio (SNR) of the signal. The stopping mechanism is determined by a two-tailed Fisher-z correlation test, with effective sample size correction in the presence of autocorrelation and modulation based on SNR, to ensure the stability of the adaptive system against non-stationary noise. The filter is evaluated on simulated signal datasets and real-world measured data. Compared with the conventional LMS filter configuration under the tested simulated conditions, the proposed architecture reduces mean squared error (MSE) by 38-82% and mean absolute error (MAE) by 15-45%, while improving both SNR and peak signal-to-noise ratio (PSNR). The execution time of the proposed method is approximately 3.5-4 times lower than that of the fixed-threshold method under the tested settings. These results indicate that the proposed method can improve the trade-off between denoising performance and computational efficiency, showing potential for low-latency implementation on resource-constrained devices.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.