Evidence map›Paper›PMID 42484980›Full record

ArticleThe Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology2026

Comparison of KONAR-multifunctional occluder and Amplatzer occluders in transcatheter closure of patent arterial ducts and ventricular septal defects.

Fatma Aboalsoud Taha, Marwa Desoky Abohamar, Raghda Ghonimy Elsheikh, Nouran Mostafa Mansour

Abstract read
In one paragraph

Article in The Egyptian heart journal : (EHJ) : official bulletin of the Egyptian Society of Cardiology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Fatma Aboalsoud TahaCardiology Department, Tanta University, Tanta, Egypt. fatma.taha@med.tanta.edu.eg.
Marwa Desoky AbohamarCardiology Department, Tanta University, Tanta, Egypt.
Raghda Ghonimy ElsheikhCardiology Department, Tanta University, Tanta, Egypt.
Nouran Mostafa MansourCardiology Department, Tanta University, Tanta, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTranscatheter closure of patent ductus arteriosus (PDA) and ventricular septal defect (VSD) is performed using various occluder devices.

objectiveWe aim to compare the use of KONAR-Multifunctional Occluder (KONAR-MFO) and Amplatzer occluders (ADO-I, ADO-II) for closure of PDAs and VSDs.

methodsThis is a retrospective study on patients who underwent transcatheter PDA or VSD closure between June 2023 and October 2025. Patients were categorized according to the occlusion device and the underlying defect. Data were analysed comprehensively.

resultsThe study included 173 patients; 116 (67.1%) and 57 (32.9%) underwent PDA and VSD closure, respectively, using 99 ADO-I, 53 KONAR-MFO, and 21 ADO-II devices. The KONAR-MFO was used in smaller, younger patients, and the ADO-I in heavier, older patients (p < 0.05). The ADO-I was used for PDA type-A (40.4%), type-E (12.1%), type-C and D (9.1% for each), as well as perimembranous and muscular VSDs (13.1% each). The KONAR-MFO was used for peri-membranous VSDs (47.2%), Gerbode-type VSDs (5.7%), and PDA type-B (14.1%). The ADO-II was employed for PDA type-E (57.1%) and type-C (42.9%), without use in VSDs. The KONAR-MFO and ADO-II devices showed the shortest procedural and fluoroscopy times with the lowest contrast use, owing to single-access deployment without arteriovenous loop formation. Freedom from all types of complications was 73.9%, 71.1%, and 66.7% for KONAR-MFO, ADO-I, and ADO-II, respectively. In ADO-I, residual shunt, device embolization, and complete heart block occurred in 2.0% each. In KONAR-MFO, left pulmonary artery (LPA) stenosis and mild aortic regurgitation were observed in 3.8% each, while residual shunt and device embolization were observed in 1.9%. ADO-II was associated with the highest residual shunt and device embolization, both occurring at 9.5%.

conclusionsADO-I was used to close PDA and VSD, with longer procedural times. KONAR-MFO offered useful applications across complex VSDs with safety profiles in smaller, younger patients. ADO-II was preferred for tubular and elongated PDAs.

Indexed as

Amplatzer devicesKONAR-multifunctional occluderPatent ductus arteriosusTranscatheter closureVentricular septal defect

Identifiers

PMID42484980
PMCPMC13391473

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.