Evidence map›Paper›PMID 42482879›Full record

ReviewJournal of clinical and experimental dentistry2026

Performance of Electronic Apex Locators, Root ZX3, NovApex N31, and Apex-S, in Irrigant Solutions of Varying Conductivity.

Lucas Rodrigues de Araújo Estrela, Luciano Tavares Ngelo Cintra, Bruno Correa Azevedo, Giuliano Caixeta Serpa, Patrícia Correa Siqueira, Júlio Almeida Silva, Daniel Almeida Decurcio, Carlos Estrela

Abstract readReview
In one paragraph

Review in Journal of clinical and experimental dentistry, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Lucas Rodrigues de Araújo EstrelaDDS, MSc. Universidade Estadual Paulista - UNESP, Department of Endodontics, Araçatuba, SP, Brazil.
Luciano Tavares Ngelo CintraUniversidade Estadual Paulista - UNESP, Department of Endodontics, Araçatuba, SP, Brazil.
Bruno Correa AzevedoDDS, MSc. IB Bender Postdoctoral Endodontic Program, Albert Einstein Medical Center, Philadelphia, Pennsylvania, USA.
Giuliano Caixeta SerpaDDS, MSc, PhD. Professor of Endodontics, Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil.
Patrícia Correa SiqueiraDDS, MSc, PhD. Professor of Endodontics, Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil.
Júlio Almeida SilvaDDS, MSc, PhD. Professor of Endodontics, Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil.
Daniel Almeida DecurcioDDS, MSc, PhD. Professor of Endodontics, Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil.
Carlos EstrelaDDS, MSc, PhD. Professor of Endodontics, Department of Stomatology Sciences, Federal University of Goiás, Goiânia, Brazil.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The success of root canal treatment depends on precise control of the working length (WL), as it directly influences periapical healing and long-term prognosis. Optimal outcomes are achieved when obturation ends short of the radiographic apex, which requires accurate WL determination. This study evaluated the performance of electronic apex locators (EALs) in irrigant solutions with different electrical conductivities. Materials and Methods: Twenty human mandibular central incisors were assessed using Root ZX3®, NovApex N31®, and Apex-S®. Standardized reference lengths were established from the incisal edge to the root apex with a digital micrometer (DM). A size 15 K-file attached to each EAL was inserted into the canals until the devices indicated the apical foramen. The silicone stoppers were adjusted to the incisal edge, and the files were removed to measure the length with the DM. The differences between the lengths measured by the EALs and the actual WL were calculated. Statistical analysis was performed using the Friedman test followed by Tukey's post-hoc test, and the Kruskal-Wallis test with the Student-Newman-Keuls post-hoc test. The significance level was set at = 0.05. Results: Root ZX3® showed the highest accuracy (p < 0.05), regardless of the irrigating solution tested. No significant differences were found between NovApex N31® and Apex-S® (p > 0.05). When deionized water was used, both NovApex N31® and Apex-S® demonstrated minimal interference, whereas significant differences were observed with 2.5% NaOCl and Triton®. Conclusions: Root ZX3® demonstrated consistent accuracy across all irrigating solutions. NovApex N31® and Apex-S® performed similarly in deionized water but showed differences when compared with 2.5% NaOCl and Triton®.

Identifiers

PMID42482879
PMCPMC13386434

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.