ArticleSmall (Weinheim an der Bergstrasse, Germany)2026
Material Extrusion-Enabled Soft Multimodal Pressure Sensors With Fabrication-Embedded Stretch-Induced Strain Insensitivity.
Article in Small (Weinheim an der Bergstrasse, Germany), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Key challenges in stretchable pressure sensors include establishing cost-effective fabrication routes for soft functional materials, achieving strain-insensitive performance under deformation, and enabling seamless integration into soft architectures. Here, electrospinning is combined with liquid-based material extrusion (l-MEX) and melt-based material extrusion (m-MEX) to fabricate stretchable pressure sensors with multimodal sensing capability. The sensing layer is composed of mechanically anisotropic electrospun poly(vinylidene fluoride) / thermoplastic polyurethane composite microfibers sandwiched between l-MEX printed stretchable silver electrodes, exhibiting a Young's modulus as low as 0.5 MPa. A three-dimensional serpentine architecture reconfigures the sensing layer into a compliant geometry and enables system-level stretchability while maintaining stable sensing performance under strain. In the capacitive mode, the optimized sensor achieves 97.6% strain insensitivity under strains up to 30% and a minimum detectable pressure of 0.04 kPa. In the piezoelectric mode, the same device exhibits a sensitivity of 16.5 mV kPa
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.