ArticleAdvanced healthcare materials2026
Portable Molecularly Imprinted Polymer Sensor for Rapid Swab-Based Detection of Norovirus.
Article in Advanced healthcare materials, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors.
Funding
Abstract
Norovirus poses a continuous challenge for healthcare systems, leading to increased hospital admissions, infection-control demands, and costly outbreak management. Gold-standard diagnostics such as real-time reverse transcriptase polymerase chain reaction (RT-PCR) require specialized laboratory equipment and trained personnel. This work reports a portable electrochemical sensor based on an electropolymerized molecularly imprinted polymer fabricated directly on an electrode surface for rapid norovirus detection using voltametric read-out. The sensor was tested against four norovirus virus-like particle (VLP) genotypes that each exhibited consistent responses across a broad concentration range. Sensor specificity and selectivity were demonstrated through comparison with a nontarget imprinted control polymer and testing against four nontarget live viruses. The imprinted polymer electrodes showed excellent stability, with no significant loss of performance after storage under ambient conditions for up to three months. For practical applicability, nitrile gloves were inoculated with each VLP genotype and sampled using standard swabbing procedures. The entire process was completed in ∼ 15 min, with electrochemical acquisition completed in 20 s. Successful detection of each genotype was achieved with detection limits between 154 and 279 fg/mL (8.78 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.