Evidence map›Paper›PMID 42482419›Full record

ArticleMedical physics2026

Performance of detector modules designed for the NeuroSphere brain PET system.

Magdelena S Allen, Larry Byars, Lukas Rauscher, Michele Scipioni, Matthew Puryear, Martin Judenhofer, Or Hen, Fabian P Schmidt, Ciprian Catana

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Magdelena S AllenAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.ORCID https://orcid.org/0009-0006-5315-5673
Larry ByarsSiemens Healthineers, Knoxville, Tennessee, USA.
Lukas RauscherWerner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany.ORCID https://orcid.org/0009-0008-1923-6474
Michele ScipioniAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0002-7625-7502
Matthew PuryearAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0001-5851-3499
Martin JudenhoferSiemens Healthineers, Knoxville, Tennessee, USA.
Or HenDepartment of Physics, Massachusetts Institute of Technology, Cambridge, Massachusetts, USA.ORCID https://orcid.org/0000-0002-4890-6544
Fabian P SchmidtWerner Siemens Imaging Center, Department of Preclinical Imaging and Radiopharmacy, Eberhard Karls University Tuebingen, Tuebingen, Germany.ORCID https://orcid.org/0000-0003-1886-4803
Ciprian CatanaAthinoula A. Martinos Center for Biomedical Imaging, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.ORCID https://orcid.org/0000-0002-3249-5971

Funding

Development of the Human Dynamic Neurochemical Connectome ScannerU01EB029826 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI CATANA, CIPRIAN · 2020 to 2025
$7.1M
NIBIB NIH HHS U01 EB029826NIH BRAIN Initiative 1U01EB029826
6 · The paper itself

Abstract

backgroundThe Human Dynamic NeuroChemical Connectome (HDNCC) scanner integrates a high spatio-temporal resolution dedicated brain PET insert (NeuroSphere PET) with a commercial 7-T MRI to enable studies of neurochemical dynamics simultaneously with functional MRI on comparable timescales. PURPOSE: The NeuroSphere will achieve unprecedented sensitivity with a spherical geometry and novel detectors, which must provide time-of-flight (TOF) and depth-of-interaction (DOI) encoding without compromising crystal separation or energy resolution. We aim to develop a novel PET module for high-resolution PET/MR applications with TOF and DOI capability.

methodsThe NeuroSphere PET detector is a 10 × 10 array of 26.0-mm LSO crystals with 1.6-mm pitch coupled to a 4 × 4 SiPM array with 4-mm pitch, and a top light guide that provides DOI encoding via light sharing. Time-to-digital converter (TDC) performance and nonlinearity correction methods were evaluated with a pulsed laser. Crystal separation, energy resolution, and DOI resolution were evaluated, including a DOI-based energy correction. The ASIC readout parameters were configured and timing corrections were implemented to optimize coincidence timing resolution (CTR), including a DOI-based timing correction.

resultsThe TDC achieved 55-ps CTR between laser pulses after implementing nonlinearity correction, an improvement to the factory correction. The PET detector had good crystal identification with a peak-to-valley ratio of 11.43

conclusionsThis work has shown the capability of the NeuroSphere PET module to provide energy resolution, DOI encoding, and TOF PET competitive with other dedicated brain PET/MR systems. The CTR of

Indexed as

BrainPositron-Emission TomographyEquipment DesignHumansImage Processing, Computer-Assisteddetector physicsPET instrumentationPET/MR

Identifiers

PMID42482419
PMCPMC13389353

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.