Evidence map›Paper›PMID 42482365›Full record

ArticleMedical physics2026

Multiscale frequency attention transformer for resolution enhancement in magnetic particle imaging.

Wenjing Jiang, Jinzhuang Xu, Xiaoli Yang, Ning He, Moritz Wildgruber, Jing Zhong, Jianshe Zhao, Xiaopeng Ma

Abstract read
In one paragraph

Article in Medical physics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Wenjing JiangSchool of Control Science and Engineering, Shandong University, Jinan, Shandong, China.
Jinzhuang XuSchool of Control Science and Engineering, Shandong University, Jinan, Shandong, China.
Xiaoli YangWeifang Xinli Superconducting Magnet Technology Co., Ltd, Weifang, China.
Ning HeSchool of Life Science and Technology, Xidian University, Xi'an, Shaanxi, China.
Moritz WildgruberKlinikum der Universität München, Munich, Germany.
Jing ZhongSchool of Instrumentation and Opto-Electronic Engineering, and Ministry of Education Key Laboratory of Precision Opto-Mechatronics Technology, Beihang University, Beijing, China.
Jianshe ZhaoChildren's Hospital Affiliated to Shandong University, Jinan, Shandong, China.
Xiaopeng MaSchool of Control Science and Engineering, Shandong University, Jinan, Shandong, China.

Funding

National Key R&D Program of China 2025YFC2426200National Natural Science Foundation of China 82227802Taishan Industrial Experts Program
6 · The paper itself

Abstract

backgroundMagnetic particle imaging (MPI) is an emerging functional imaging modality that enables high-resolution (HR) visualization of superparamagnetic iron oxide nanoparticles (SPIONs). It offers significant advantages, including high penetration capability, absence of ionizing radiation, high contrast, and exceptional temporal resolution and sensitivity, making it highly promising for a broad spectrum of biomedical and clinical applications. PURPOSE: Although MPI holds great promise, fundamental spatial resolution is inherently constrained by the gradient field strength and the saturation magnetization physics of the SPIONs. To address the image blurring characterized by the system's point spread function (PSF) and the dependency on high-gradient fields for HR imaging, this study aims to develop a robust deep learning framework to reduce reliance on high gradient hardware. We aim to achieve high-fidelity resolution enhancement computationally, recovering fine structural details from low-resolution inputs, thereby bypassing the need for costly hardware upgrades.

methodsWe propose a Multiscale Frequency Attention Transformer (MFAT) model, which integrates a frequency-domain discriminative feedforward network (DFFN) with a multiscale attention block (MAB) to form an end-to-end framework for recovering HR MPI images from low-resolution reconstructions. The MFAT architecture combines multiscale feature aggregation with a novel frequency attention mechanism, allowing it to capture both global context and fine local details across multiple scales while enhancing fidelity and sharpness in the frequency domain.

resultsExtensive evaluations using both simulated and real-world MPI data demonstrate that the proposed MFAT model outperforms existing state-of-the-art deep learning methods, achieving an improvement of 7.51% in peak signal-to-noise ratio (PSNR) in the MNIST dataset, corresponding to a gain of 2.48 dB over the second strongest baseline. Furthermore, in terms of spatial resolution, MFAT significantly reduced the full width at half maximum (FWHM) by 17.86% on the complex FIVES vascular structures compared to the second-performing baseline, verifying its superior capability in recovering high-frequency details.

conclusionsThus, MFAT provides an effective solution for enhancing spatial resolution in MPI image reconstruction and significantly improves image quality. This advancement holds strong potential to facilitate the translation of MPI technology into more refined clinical applications.

Indexed as

Deep LearningImage Processing, Computer-AssistedMagnetic Particle ImagingSignal-To-Noise Ratioimage reconstructionmagnetic particle imagingresolution enhancementTransformer

Identifiers

PMID42482365
PMCPMC13389105

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.