Evidence map›Paper›PMID 42482206›Full record

ArticleBMC musculoskeletal disorders2026

Development and evaluation of a modified injectable calcium phosphate cement with enhanced injectability and mechanical stability for bone defect repair.

Xiaoli Zhou, Dong Wei, Zepei Zhang, Yinghua Liu, Jun Miao, Zhiyong Qian

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Xiaoli Zhou *Department of Toxicology, Tianjin Centers for Disease Control and Prevention, and NHC Specialty Laboratory of Food Safety Risk Assessment and Standard Development (Tianjin), No. 6 Huayue Road, Tianjin, 300011, China.
Dong Wei *Department of Orthopedics Surgery, Tianjin Academy of Traditional Chinese Medicine Affiliated Hospital, No. 354 Beima Road, Tianjin, 300120, China.
Zepei ZhangDepartment of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Road, Hexi District, Tianjin, 300211, China.
Yinghua LiuDepartment of Toxicology, Tianjin Centers for Disease Control and Prevention, and NHC Specialty Laboratory of Food Safety Risk Assessment and Standard Development (Tianjin), No. 6 Huayue Road, Tianjin, 300011, China.
Jun MiaoDepartment of Spine Surgery, Tianjin Hospital, Tianjin University, No. 406 Jiefang South Road, Hexi District, Tianjin, 300211, China. mj6688@tju.edu.cn.
Zhiyong QianDepartment of Toxicology, Tianjin Centers for Disease Control and Prevention, and NHC Specialty Laboratory of Food Safety Risk Assessment and Standard Development (Tianjin), No. 6 Huayue Road, Tianjin, 300011, China. tjcdcdl@163.com.

Funding

Tianjin Health Research Project TJWJ2025MS041Tianjin Key Medical Discipline Construction Project YXZDXK-3-034C
6 · The paper itself

Abstract

This study aimed to optimize an injectable carbonated hydroxyapatite cement for metaphyseal bone defect filling and to evaluate its biomechanical performance in distal radius fracture fixation. Six food- or pharmaceutical-grade additives, including sodium alginate, glycerol, astragalus gum, xanthan gum, citric acid, and hydroxypropyl methylcellulose (HPMC), were screened to improve injectability while maintaining setting behavior and mechanical strength. Among them, 2% HPMC provided the best overall performance, increasing injectability to approximately 95% without markedly affecting setting time or compressive strength. The optimized injectable carbonated hydroxyapatite cement (ICHA) was then tested in a standardized human cadaveric distal radius fracture-defect model using three fixation strategies: K-wire fixation alone, ICHA cement alone, and combined ICHA + K-wire fixation. Within a 10° torsion range, the ICHA and ICHA + K-wire groups showed higher torsional stiffness and maximum torque than the K-wire-only group, although peak torque occurred at smaller torsion angles. Under physiological compression, the groups showed comparable stability, whereas ICHA-containing groups showed greater resistance under higher compression. These findings suggest that 2% HPMC-modified ICHA may serve as an injectable metaphyseal void filler and structural adjunct to conventional K-wire fixation.

Indexed as

Bone CementsCalcium PhosphatesFracture Fixation, InternalRadius FracturesBiomechanical PhenomenaCompressive StrengthHumansInjectionsMaterials TestingBone Cementscalcium phosphateCalcium PhosphatesAdditiveBiomechanicsICHARadial fracture

Identifiers

PMID42482206
PMCPMC13474720

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.