Evidence map›Paper›PMID 42479362›Full record

ArticleJournal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing2026

Needle-in-needle micropuncture technique for epicardial access during ventricular tachycardia ablation.

Roland Richard Tilz, Roman Mamaev, Sascha Hatahet, Tuğba Aktemur Özalp, Sorin Stefan Popescu, Jan-Per Wenzel, Mirco Küchler, Charlotte Eitel, Karl-Heinz Kuck, Kohei Ukita

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Roland Richard Tilz *Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Roman Mamaev *Department of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Sascha HatahetDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Tuğba Aktemur ÖzalpDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Sorin Stefan PopescuDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Jan-Per WenzelDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Mirco KüchlerDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Charlotte EitelDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Karl-Heinz KuckDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany.
Kohei UkitaDepartment of Rhythmology, University Heart Center Lübeck, University Hospital Schleswig-Holstein, Lübeck, Germany. u9017k@gmail.com.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundEpicardial access is often required for catheter ablation of ventricular tachycardia (VT) when arrhythmogenic substrates are located on the epicardial surface, but it is associated with potentially serious complications, including cardiac tamponade and coronary artery injury. The use of a needle-in-needle (NiN) micropuncture technique for percutaneous epicardial access may reduce myocardial trauma and improve procedural safety. We aimed to describe a standardized workflow and assess the feasibility and acute safety of epicardial access for VT ablation using a NiN micropuncture technique.

methodsThis retrospective, single-center observational study without a comparator group included 40 consecutive patients who underwent epicardial access for VT ablation using the NiN micropuncture technique between January 2020 and July 2025. Baseline clinical characteristics, procedural details, success of epicardial access, and acute access-related complications were evaluated.

resultsNurse-administered propofol sedation was used in 37 patients (93%). The median total procedure time was 141 min. Epicardial access was successfully achieved in all patients (100%). No major access-related complications occurred, including cardiac tamponade, significant bleeding, or coronary artery injury. One patient developed complete atrioventricular block during epicardial ablation, which was unrelated to the access technique. All patients were discharged without procedure-related disability or death.

conclusionEpicardial access using a NiN micropuncture technique was feasible and acutely safe for VT ablation, achieving a 100% access success rate with no major puncture-related complications.

Indexed as

Catheter ablationComplete atrioventricular blockEpicardial approachMicropuncture techniqueVentricular tachycardia

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.