Photon-counting CT for hepato-bilio-pancreatic imaging: a qualitative head-to-head comparison with third-generation dual-source CT: preliminary results.

Giovanni Foti, Flavio Spoto, Alessandro Spezia, Leonardo Monterubbiano, Giuseppe Sala, Emanuele Demozzi, Chiara Longo, Carmelo Cicciò, Nicolò Cardobi, Riccardo De Robertis and 1 more

Abstract read
PubMed Publisher
In one paragraph

Article in La Radiologia medica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors.

Giovanni FotiDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Flavio SpotoDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy. flaviospoto@hotmail.it.ORCID http://orcid.org/0009-0003-9846-8145
Alessandro SpeziaDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Leonardo MonterubbianoDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Giuseppe SalaDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Emanuele DemozziDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Chiara LongoDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Carmelo CicciòDepartment of Radiology, IRCCS Sacro Cuore-Don Calabria Hospital, Via Don A. Sempreboni, 5, 37024, Negrar Di Valpolicella, Verona, Italy.
Nicolò CardobiRadiology - Department of Diagnostics and Public Health , GB Rossi Hospital AOUI - University of Verona, Piazzale L.A. Scuro, 10, 37134, Verona, Italy.
Riccardo De RobertisRadiology - Department of Diagnostics and Public Health , GB Rossi Hospital AOUI - University of Verona, Piazzale L.A. Scuro, 10, 37134, Verona, Italy.
Mirko D'OnofrioRadiology - Department of Diagnostics and Public Health , GB Rossi Hospital AOUI - University of Verona, Piazzale L.A. Scuro, 10, 37134, Verona, Italy.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo compare qualitative reader-based image quality and anatomical detail of hepato-bilio-pancreatic structures between photon-counting detector CT (PCCT) and third-generation dual-source energy-integrating detector CT (EID-CT) in the same patient cohort. MATERIALS AND

methodsThis retrospective, single-center qualitative study included 25 patients who underwent contrast-enhanced abdominal CT with both PCCT (Siemens NAEOTOM Alpha pro) and EID-CT (Siemens SOMATOM Force) within a 3-month interval using comparable acquisition protocols, with the exception of reconstructed section thickness (0.4-0.6 mm for PCCT vs 1.0 mm for EID-CT). Four independent radiologists (two with > 10 years and two with < 5 years of experience) evaluated six parameters using a five-point Likert scale: overall image quality, arterial vascular visualization, venous vascular visualization, pancreatic ductal tree, biliary ductal tree, and peripancreatic lymph nodes. All readers were blinded to scanner type. Paired t-tests and non-parametric Wilcoxon signed-rank tests compared mean scores between PCCT and EID-CT. Inter-reader agreement was assessed using intraclass correlation coefficients. Statistical significance was set at p < 0.05. No quantitative image metrics or diagnostic performance outcomes were assessed; analyses were limited to reader-based Likert scale image quality scores.

resultsPCCT demonstrated statistically significant superiority across all six parameters compared with EID-CT (overall image quality 4.82 vs 3.80, arterial vascular visualization 4.87 vs 3.98, venous vascular visualization 4.84 vs 3.91, pancreatic ductal tree 4.83 vs 3.51, biliary ductal tree 4.87 vs 3.63, peripancreatic lymph nodes 4.86 vs 3.81; all p < 0.0001). Mean score improvements with PCCT ranged from 0.89 to 1.32 points across all parameters. Inter-reader agreement was good to excellent for PCCT (ICC 0.70-0.92) and poor to moderate for EID-CT (ICC 0.43-0.70). Reader experience level did not significantly influence assessments (p = 0.94). These findings derive from a qualitative head-to-head comparison of image quality scores and were consistent across all four readers.

conclusionIn this preliminary intra-patient comparison, photon-counting CT provided significantly superior image quality and anatomical detail in the hepato-bilio-pancreatic region compared to third-generation dual-source EID-CT. Enhanced visualization of ductal structures, distal vessels, and lymph nodes may support improved diagnostic confidence and more precise staging, although diagnostic performance was not assessed in this study. Because reconstructed section thickness differed between systems, these qualitative advantages cannot be attributed to detector technology alone and require confirmation in larger studies with matched protocols and diagnostic-accuracy endpoints.

Indexed as

Abdominal imagingBiliary treeEnergy-integrating detector CTHepato-bilio-pancreatic imagingImage qualityPancreatic ductal systemPhoton-counting computed tomography