Evidence map›Paper›PMID 42474578›Full record

ArticleJournal of robotic surgery2026

Optimizing robotic cholecystectomy: improving cost-effectiveness with non-inferior safety and efficacy.

Ron Dar, Zakhar Bramnick, Assi Drobot, Barak Levit, Wisam Sbeit, Moaad Farraj

Abstract read
In one paragraph

Article in Journal of robotic surgery, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ron DarDepartment of General Surgery, Tzafon Medical Center, Lower Galilee, Israel. rondar@hfhosp.org.
Zakhar BramnickDepartment of General Surgery, Galilee Medical Center, Nahariya, Israel.
Assi DrobotDepartment of General Surgery, Tzafon Medical Center, Lower Galilee, Israel.
Barak LevitDepartment of General Surgery, Tzafon Medical Center, Lower Galilee, Israel.
Wisam SbeitAzrieli Faculty of Medicine, Bar Ilan University, Safed, Israel.
Moaad FarrajDepartment of General Surgery, Galilee Medical Center, Nahariya, Israel.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Achieving the critical view of safety during cholecystectomy is paramount for preventing bile duct injury but contingent on effective gallbladder retraction. Although robotic platforms offer enhanced dexterity and visualization, they present an opportunity to improve the static retraction methods common in laparoscopy. Herein, we describe our advanced dynamic multidimensional retraction (DMR) technique for three-port robotic cholecystectomy. This method uses the external joints of the robotic arms to provide continuous, multi vector exposure of the triangle of Calot, aiming to enhance surgical safety and efficiency. We conducted a retrospective review of the first 131 consecutive patients who underwent a three-port robotic cholecystectomy using our standardized DMR technique between January 2023 and July 2025. All procedures were performed on the DaVinci Xi or X platform by four surgeons during their initial robotic case series. Key demographic, intraoperative, and postoperative data were analyzed. Primary outcome measures included console times, length of hospital stay, intraoperative complications, and conversion rate to other surgical techniques. We performed 131 standardized robotic cholecystectomies via three-arm robot deployment by four teams. The mean patient age was 53 years; 50 were men and 81 were women. All teams started their robotic surgeries sequentially in a 4-months period in 2023. Most cases were elective, seven patients had acute cholecystitis, and 35 patients had a cholecystectomy integrated with other procedures like intraoperative cholangiogram, liver biopsy, repair of postoperative ventral hernia and one case of internal hernia repair after bariatric surgery. The mean console time was 57 min. There was no conversion to other surgical techniques. DMR is a safe and reproducible technique for three-port robotic cholecystectomy. By leveraging the robotic platform capabilities, our method provides non-inferior exposure of the critical anatomy. This advanced robotic approach represents a valuable tool for optimizing the surgical field and may improve safety and efficiency during robotic cholecystectomy. Further investigation in larger, comparative studies is warranted.

Indexed as

CholecystectomyCholecystectomy, LaparoscopicCost-Benefit AnalysisRobotic Surgical ProceduresAdultAgedFemaleHumansLength of StayMaleMiddle AgedOperative TimeRetrospective StudiesTreatment OutcomeMultidimensional retractionRobotic cholecystectomyRobotic surgery

Identifiers

PMID42474578
PMCPMC13384971

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.