Evidence map›Paper›PMID 42469722›Full record

ArticleBMC musculoskeletal disorders2026

Reinforcement K-wires reduce the risk of tibial plateau and lateral cortex fractures during open wedge high tibial osteotomy: a prospective comparative cohort study.

Ebeed Yasin, Ahmed Darweash, Mohamed Salman, Alaa Abououf, Mohamed Abdel-Wahed, Hosam El-Din Amin

Abstract readComparative StudyMulticenter Study
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ebeed YasinAswan University, Aswan Government, Aswan, Egypt.
Ahmed DarweashSuez University, Suez Government, Suez, Egypt. ahmed.darweash@med.suezuni.edu.eg.
Mohamed SalmanAswan University, Aswan Government, Aswan, Egypt.
Alaa AbououfAswan University, Aswan Government, Aswan, Egypt.
Mohamed Abdel-WahedCairo University, Cairo Government, Cairo, Egypt.
Hosam El-Din AminEl-Sahel Teaching Hospital, Cairo Government, Cairo, Egypt.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundOpen wedge high tibial osteotomy (OWHTO) may be complicated by iatrogenic fractures of the tibial plateau or lateral cortex, potentially compromising osteotomy stability. Reinforcement with intra-operative Kirschner wire (K-wire) has been proposed to mitigate this risk, but robust clinical evidence is limited. This study aimed to evaluate whether intra-operative reinforcement wires decrease the incidence of iatrogenic fractures during OWHTO and to assess their impact on clinical and radiological outcomes.

methodsA prospective multi-centre comparative cohort study was conducted between March 2023 and March 2024, including 68 patients (72 initially enrolled) with medial knee compartment osteoarthritis and genu varum undergoing OWHTO who met predefined radiological and clinical criteria. Patients were allocated to a reinforcement group (Group A, n = 34; OWHTO with subchondral and lateral hinge K-wire reinforcement) and a control group (Group B, n = 34; OWHTO without reinforcement). Outcomes included intra-operative iatrogenic tibial plateau and lateral cortex fractures, weight-bearing milestones, radiographic parameters (medial proximal tibial angle (MPTA), mechanical axis deviation (MAD), posterior tibial slope), Lysholm knee scores at serial follow-up, and complications.

resultsBaseline demographics, comorbidities, and most intraoperative variables (excluding iatrogenic fractures) did not differ significantly between the reinforcement (Group A) and non-reinforcement (Group B) groups. No iatrogenic fractures of the tibial plateau or lateral cortex occurred in Group A, whereas 9 of 34 patients (26.5%) in Group B sustained such fractures (three each of Takeuchi types 1-3), with 6 of these 9 requiring additional lateral plating (P = 0.002). Patients in Group A achieved partial weight-bearing significantly earlier than those in Group B (P = 0.014), whereas Lysholm scores showed no significant differences between groups across all follow-up periods. Both groups exhibited comparable improvements MPTA, MAD, posterior tibial slope, and final Lysholm scores. Rates of wound complications and iliac crest bone graft harvest were similar between groups.

conclusionIntraoperative reinforcement of the tibial plateau and lateral cortex with subchondral and lateral hinge K-wires effectively reduced the risk of iatrogenic fractures in OWHTO and is associated with improved early functional recovery without adversely affecting alignment, union, or complication rates. These findings support the incorporation of K-wire reinforcement as a simple, reproducible adjunct to enhance the safety of OWHTO in appropriately selected patients.

Indexed as

Bone WiresOsteoarthritis, KneeOsteotomyTibiaTibial FracturesAgedFemaleGenu VarumHumansIatrogenic DiseaseMaleMiddle AgedProspective StudiesTibial Plateau FracturesIatrogenic fracturesLateral cortexLateral hingeLysholm scoreMedial compartment osteoarthritisOpen wedge high tibial osteotomyOsteotomy stabilityReinforcement K-wiresTibial plateau