Evidence map›Paper›PMID 42469714›Full record

ArticleBMC musculoskeletal disorders2026

A novel pedicle-PMMA-augmented screw resists reverse windshield-wiper failure in osteoporotic spine fixation: parameter optimization by finite element analysis.

Dongsheng Wang, Jian Zhang, Bo Huang, Liang Zhang, Jiming Liu, Baiyi Liu, Peng Liu, Yaoyao Liu

Abstract read
In one paragraph

Article in BMC musculoskeletal disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Dongsheng Wang *Department of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China.
Jian Zhang *Department of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China.
Bo HuangDepartment of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China.
Liang ZhangDepartment of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China.
Jiming LiuChongqing Brief Technology Co., Ltd, Chongqing, China.
Baiyi LiuDepartment of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China.
Peng LiuDepartment of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China. liupengd@tmmu.edu.cn.
Yaoyao LiuDepartment of Spine Surgery, Center of Orthopedics, Daping Hospital, Chongqing Key Laboratory of Spinal Disease Therapy and Regeneration (Military-Civilian), Army Medical University, Third Military Medical University, Chongqing, China. dpliuyaoyao@tmmu.edu.cn.

Funding

Daping Hospital Science Foundation ZXZYTSLC10National Natural Science Foundation of China 81902257Natural Science Foundation of Chongqing 2024TIAD-KJFZMSX0076
6 · The paper itself

Abstract

backgroundConventional PMMA-augmented pedicle screws (CPPS) remain susceptible to "reverse windshield-wiper" failure in severe osteoporosis. This study aimed to elucidate this failure mechanism and develop a novel pedicle-PMMA-augmented screw (PPAS) with enhanced biomechanical stability under FE analysis.

methodsAn L4 vertebral finite element (FE) model incorporating threaded hollow-core CPPS with anterior injection holes was established, followed by simulation of PMMA diffusion characteristics. Under 100 N craniocaudal cyclic loading, screw stress distribution and displacement were recorded, with the stress concentration point (designated as Point P) identified. Additional injection holes were defined at Point P to determine the maximum PMMA volume (0.3 mL). Subsequently, 30 PMMA-augmented FE models with additional variable injection locations (P-2 to P + 3 screw pitches) and volumes (0.06-0.30 mL in 0.06 mL increments) were established to analyze screw stress distribution and displacement under craniocaudal loads for optimization of parameters and screw design.

resultsUnder 100 N craniocaudal cyclic loading, FE analysis demonstrated that threaded CPPS with 1.5 mL PMMA reduced screw-tip stress, shifted the primary stress concentration from the screw tip to the narrowest pedicle notch region (Point P), and decreased screw-tail displacement. Augmentation with 0.3 mL PMMA at Point P achieved PMMA-cortex contact. FE analysis indicated that additional augmentation at this point substantially reduced screw displacement and bone stress under craniocaudal loading. Parametric analysis revealed minimal screw-tail displacement with 0.24-0.30 mL PMMA at points P or P + 1, and minimal bone stress with 0.24-0.30 mL PMMA at point P.

conclusionsThe failure mechanism of CPPS in severe osteoporosis involves a "reverse windshield-wiper" effect, driven by stress concentration in the pedicle region resulting from screw anterior PMMA-augmentation. Our novel PPAS with dedicated PMMA injection holes at the narrowest pedicle notch regions offers a computational proof-of-concept for an alternative fixation strategy to prevent this failure mode.

Indexed as

Finite Element AnalysisLumbar VertebraeOsteoporosisPedicle ScrewsPolymethyl MethacrylateBiomechanical PhenomenaHumansStress, MechanicalPolymethyl MethacrylateAugmentationFinite elementOsteoporoticPedicle screwWindshield-wiper

Identifiers

PMID42469714
PMCPMC13660034

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.