Evidence map›Paper›PMID 42465606›Full record

ArticleOptica2026

Maskless and on-chip LED-array microscope with spatially varying angle calibration for centimeter-scale phase imaging.

Sibi Chakravarthy Shanmugavel, Vindya Senanayake, Donghwa Suh, Jeffrey M Gross, Shwetadwip Chowdhury

Abstract read
In one paragraph

Article in Optica, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

5 authors.

Sibi Chakravarthy ShanmugavelChandra Department of Electrical and Computer Engineering, UT Austin, Austin, Texas 78712, USA.ORCID 0009-0003-1719-7014
Vindya SenanayakeDepartment of Molecular Biosciences, University of Texas at Austin, Austin, Texas 78712, USA.ORCID 0009-0001-1530-8310
Donghwa SuhDepartment of Molecular Biosciences, University of Texas at Austin, Austin, Texas 78712, USA.ORCID 0009-0006-9593-2901
Jeffrey M GrossDepartment of Molecular Biosciences, University of Texas at Austin, Austin, Texas 78712, USA.
Shwetadwip ChowdhuryChandra Department of Electrical and Computer Engineering, UT Austin, Austin, Texas 78712, USA.ORCID 0000-0002-6142-0231

Funding

Elucidating the Molecular Underpinnings of Endogenous RPE RegenerationR01EY029410 · NEI · UNIVERSITY OF TEXAS AT AUSTIN · PI Jeffrey Gross · 2019 to 2026
$2.4M
Epigenetic Regulation of Retinal RegenerationR01EY035888 · NEI · UNIVERSITY OF TEXAS AT AUSTIN · PI Jeffrey Gross · 2024 to 2026
$1.2M
Imaging deep-tissue morphogenesis at whole-organism scalesR35GM155424 · NIGMS · UNIVERSITY OF TEXAS AT AUSTIN · PI Shwetadwip Chowdhury · 2024 to 2026
$1.0M
Computational Framework to Enhance Antenna-based Electromagnetic ImagingR21EB033629 · NIBIB · UNIVERSITY OF TEXAS AT AUSTIN · PI CHOWDHURY, SHWETADWIP, PORTER, EMILY · 2023 to 2023
$418k
NEI NIH HHS R01 EY029410NEI NIH HHS R01 EY035888NIBIB NIH HHS R21 EB033629NIGMS NIH HHS R35 GM155424
6 · The paper itself

Abstract

Conventional lens-based microscopes are constrained by a trade-off between resolution and field-of-view (FOV), which limits overall imaging throughput. Recent works have shown that on-chip imaging systems with LED-array-based illumination offer a cost-effective approach for large FOV phase imaging. However, this strategy faces two main challenges: (1) twin-image ambiguity can degrade phase reconstruction. While mask-based modulation can help, it adds system complexity due to fabrication and alignment requirements; and (2) the illumination angle from each LED varies across large FOVs and can degrade centimeter-scale phase reconstruction without calibration. Here, we present a computational framework to jointly achieve mask-free on-chip phase imaging and adaptive calibration of spatially varying illumination angles. The sensorFOVis divided into subregions, within each of whichLEDillumination is approximated as planar. LED illumination angles for each subregion are initialized geometrically. Phase retrieval is then performed within each subregion by constraining the reconstruction with a soft optical transparency prior while simultaneously refining angle estimates. Reconstructed phase maps are merged to produce a high-quality, large-FOV phase image. We demonstrate this approach by achieving centimeter-scale on-chip phase imaging (up to 2.7 × 1.7 cm

Identifiers

PMID42465606
PMCPMC13375108

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.