ArticleAbdominal radiology (New York)2026
Dual-energy CT with metal artifact reduction for post-EVAR CTA surveillance: a prospective study with image quality analysis.
Article in Abdominal radiology (New York), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeTo evaluate the value of dual-energy computed tomography (DECT) combined with the iterative metal artifact reduction (iMAR) for postoperative endovascular aortic repair (EVAR) CT angiography (CTA) surveillance.
methodsIn this prospective study, post-EVAR CTA surveillance was performed using a Siemens Force CT (100/150 kVp dual-energy). Images were reconstructed as conventional mixed and 40-190 keV virtual monoenergetic images (VMIs), with and without iMAR. Image quality was assessed via quantitative parameters and 5-point subjective scores, with clinical data and radiation dose recorded simultaneously. Diagnostic performance was referenced to surgical/DSA findings and blinded expert adjudication. Statistical analysis was performed via two-way repeated-measures ANOVA with post-hoc paired t-tests or Wilcoxon tests for quantitative parameters, While subjective scores were analyzed using the Friedman test with post-hoc Wilcoxon signed-rank tests. P values were Bonferroni-corrected; corrected P < 0.05 indicated significance.
resultsFifty post-EVAR patients (82% male; 68.7 ± 8.9 years) received safe radiation doses; stent type yielded no quantitative differences (P > 0.05). iMAR-DECT synergistically enhanced image quality, with improvements correlating positively with artifact severity while sparing normal tissues for iMAR. Energy levels dominated the trend: most parameters declined rapidly at 40-70 keV but plateaued beyond 100 keV. iMAR significantly outperformed non-iMAR in scores of artifact reduction (plateauing at 150-190 keV) and vessel visibility (peaking at 90 keV, P < 0.01). For diagnosis, iMAR+DECT converted five false negatives into true positives (endoleaks, thrombosis, infection), showing a trend toward higher sensitivity than those for non-iMAR+DECT (P > 0.05, large effect size).
conclusionThe integration of DECT-VMIs with the iMAR algorithm appears to improve image quality in post-EVAR CTA by effectively reducing stent-related metal artifacts while enhancing vascular and soft-tissue visualization. Based on our quantitative and qualitative assessments, an energy level of 90 keV (effective range 80-100 keV) may be considered optimal to optimize diagnostic evaluation, pending validation in larger, multi-center cohorts.