ArticleBiomedical optics express2026
Radiotherapy beam tracking by dual-modality injectable fiducial marker for X-ray CT and Cherenkov luminescence imaging.
Article in Biomedical optics express, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Accurate beam targeting is critical in radiation therapy, particularly for stereotactic treatments of mobile organs where fiducial markers are routinely used for image guidance. However, current approaches do not provide real-time confirmation that the therapeutic radiation beam is accurately delivered to the intended target during irradiation. This study presents a preliminary proof-of-concept evaluation of a dual-modality fiducial marker that combines a liquid injectable fiducial material for X-ray computed tomography (CT) contrast with a biocompatible radioluminescent ink, enabling both pre-treatment localization and intra-treatment optical verification. The proposed formulation can be delivered by syringe into anatomical sites and readily visualized on CT for treatment planning and alignment. During irradiation, Cherenkov light generated within tissue excites the marker, producing visible luminescence detectable with a time-gated imaging system and enabling Cherenkov-excited luminescence imaging (CELI) of beam position in real time. Phantom studies demonstrated detection sensitivity for injected volumes as small as 20 µL and radiation doses as low as 2.8 cGy, with measurable signals at depths up to 8 mm in tissue-mimicking media. The liquid fiducial provided clear CT visualization of the injection site prior to treatment, while CELI enabled real-time visualization of the radiation beam during irradiation in vivo. A strong spatial correlation was observed between emitted luminescence and radiation beam location. These results demonstrate the feasibility of a simple subcutaneous injectable fiducial marker system for real-time beam verification in radiation therapy using clinically Cherenkov imaging cameras.
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.