Evidence map›Paper›PMID 42460052›Full record

ArticleJournal of biomedical optics2026

Sensor-integrated dual-clad fiber probe for OCT-guided retinal endolaser photocoagulation.

Dongyue Wu, Florian Lux, Max Mai Tobon, Holger Muenz, Soeren Schmidt, Eleonora Tagliabue, Philipp Matten, Çağlar Ataman

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Dongyue WuUniversity of Freiburg, Department of Microsystems Engineering, Freiburg, Germany.ORCID https://orcid.org/0009000664856387
Florian LuxUniversity of Freiburg, Department of Microsystems Engineering, Freiburg, Germany.ORCID https://orcid.org/0000-0003-4325-5129
Max Mai TobonCarl Zeiss AG, Corporate Research & Technology, Eggenstein-Leopoldshafen, Germany.
Holger MuenzCarl Zeiss AG, Corporate Research & Technology, Oberkochen, Germany.
Soeren SchmidtCarl Zeiss AG, Corporate Research & Technology, Jena, Germany.
Eleonora TagliabueCarl Zeiss AG, Corporate Research & Technology, Eggenstein-Leopoldshafen, Germany.
Philipp MattenCarl Zeiss AG, Corporate Research & Technology, Eggenstein-Leopoldshafen, Germany.ORCID https://orcid.org/0000-0001-6874-8435
Çağlar AtamanUniversity of Freiburg, Department of Microsystems Engineering, Freiburg, Germany.ORCID https://orcid.org/0000-0002-6280-8465

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Significance: Retinal endolaser photocoagulation is a widely performed vitreoretinal procedure but currently lacks real-time intraoperative feedback on treatment outcomes. Integrating optical coherence tomography (OCT) directly into the endolaser probe enables co-localized, intraoperative sensing of tissue response during laser delivery, offering the potential to significantly enhance surgical safety and efficacy. Aim: The aim of the study is to design, fabricate, and demonstrate a fiber-optic smart instrument with a 3D nano-printed microlens and instrument-integrated OCT sensing that enables co-localized, concurrent surgical laser delivery and tomographic sensing of tissue alterations during REPC. Approach: A dual-clad fiber was used to co-axially deliver surgical and OCT beams through the outer multi-mode and inner single-mode cores. A 3D nano-printed aspherical microlens ( Results: Optical performance assessments demonstrated close alignment between measured and simulated beam profiles, with an OCT spot size of Conclusions: The miniaturized iiOCT endolaser probe combines surgical laser delivery with OCT sensing, achieving adequate performance for the targeted clinical application. This sensor-integrated instrument has the potential to enable intraocular, intraoperative, and quantitative assessment of treatment outcomes. It could support feedback-driven, robotic endolaser photocoagulation, enhancing the safety and efficacy of retinal endolaser surgery.

Indexed as

Fiber Optic TechnologyLaser CoagulationRetinaSurgery, Computer-AssistedTomography, Optical CoherenceAnimalsEquipment DesignOptical FibersPrinting, Three-DimensionalSwinedual-clad fibermicro-opticsoptical coherence tomographyretinal endolaser photocoagulationsurgical laservitreoretinal surgery

Identifiers

PMID42460052
PMCPMC13371110

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.