Evidence map›Paper›PMID 42458248›Full record

ArticleBMC cardiovascular disorders2026

Silent suppuration: an afebrile infected left anterior descending artery pseudoaneurysm with contiguous myocardial necrosis after drug-eluting stent implantation - a case report.

Sanketh Edem, Mallikarjuna Pavan Aggarapu, Sathaiah Dadi, Sachin Mahajan, Basant Kumar, Rajesh Vijayvergiya

Abstract readCase Reports
In one paragraph

Article in BMC cardiovascular disorders, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Sanketh EdemDepartment of Cardiothoracic and Vascular Surgery, Post Graduate Institute of Medical Education and Research, Chandigarh, India. sanketh.edem@gmail.com.ORCID http://orcid.org/0000-0002-4714-8868
Mallikarjuna Pavan AggarapuDepartment of Cardiothoracic and Vascular Surgery, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Sathaiah DadiDepartment of Cardiothoracic and Vascular Surgery, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Sachin MahajanDepartment of Cardiothoracic and Vascular Surgery, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Basant KumarDepartment of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.
Rajesh VijayvergiyaDepartment of Cardiology, Post Graduate Institute of Medical Education and Research, Chandigarh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundInfected coronary artery pseudoaneurysm is an uncommon but lethal complication of percutaneous coronary intervention, with a reported mortality approaching half of all cases. Fever and raised inflammatory markers are the dominant diagnostic clues, and their absence almost invariably delays diagnosis. Contiguous myocardial involvement by the suppurative process has, to our knowledge, not previously been described. CASE PRESENTATION: A 46-year-old hypertensive Indian man presented with acute exertional chest pain four weeks after drug-eluting stent implantation in the left anterior descending (LAD) artery. He was afebrile and haemodynamically stable, with normal serial total leucocyte counts, C-reactive protein, and procalcitonin; multiple blood cultures remained sterile. Coronary angiography showed a saccular pseudoaneurysm at the proximal edge of the LAD stent, and ECG-gated CT aortography confirmed a 19 × 12 mm peri-stent contrast leak. 18 F-fluorodeoxyglucose positron emission tomography-computed tomography (FDG PET-CT) demonstrated intense uptake (SUVmax 18.0) in a paracardiac soft-tissue collection abutting the stent, raising the unsuspected diagnosis of infection. At urgent operation, frank pus was evacuated from the sac and had tracked into the adjacent epicardium and superficial myocardium, producing focal myocardial necrosis that required debridement. The stent was retrieved, the proximal LAD ligated, coronary endarterectomy performed, and revascularisation achieved with an in situ left internal mammary artery (LIMA) to LAD anastomosis. Cultures grew Pseudomonas aeruginosa. Recovery was uneventful and the patient remained well at three-month follow-up.

conclusionsInfected coronary pseudoaneurysm can present with a silent inflammatory profile and may extend beyond the vessel wall into the surrounding myocardium. FDG PET-CT can be a decisive, and at times the principal, diagnostic test when conventional clinical and laboratory clues are absent. Surgical management must extend beyond sac exclusion and bypass to include debridement of contiguously infected myocardium, and benefits from arterial conduit revascularisation.

Indexed as

Aneurysm, FalseAneurysm, InfectedCoronary AneurysmDrug-Eluting StentsMyocardiumPercutaneous Coronary InterventionProsthesis-Related InfectionsPseudomonas InfectionsAnti-Bacterial AgentsCoronary AngiographyHumansMaleMiddle AgedNecrosisPositron Emission Tomography Computed TomographyTreatment OutcomeAnti-Bacterial AgentsAfebrile presentationDrug-eluting stentFDG PET-CTInfected coronary pseudoaneurysmMyocardial necrosisPseudomonas aeruginosa

Identifiers

PMID42458248
PMCPMC13651146

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked