Evidence map›Paper›PMID 42458105›Full record

ArticleEuropean journal of pediatrics2026

A quality improvement study on noise reduction in a level 3 neonatal intensive care unit.

Mélanie Forestier, Laurence Caeymaex, Fabrice Decobert, Xavier Durrmeyer, Gilles Dassieu, Manon Tauzin

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of pediatrics, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mélanie ForestierNeonatal Intensive Care Unit, CHI Créteil, Créteil, France. melanie.forestier@aphp.fr.
Laurence CaeymaexNeonatal Intensive Care Unit, CHI Créteil, Créteil, France.ORCID http://orcid.org/0000-0003-3822-5136
Fabrice DecobertNeonatal Intensive Care Unit, CHI Créteil, Créteil, France.
Xavier DurrmeyerNeonatal Intensive Care Unit, CHI Créteil, Créteil, France.ORCID http://orcid.org/0000-0002-6303-7252
Gilles DassieuNeonatal Intensive Care Unit, CHI Créteil, Créteil, France.ORCID http://orcid.org/0000-0002-1811-7771
Manon TauzinNeonatal Intensive Care Unit, CHI Créteil, Créteil, France.ORCID http://orcid.org/0000-0003-0547-4566

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In many neonatal intensive care units, newborns are exposed to many sounds, including alarms and human activity. Noise consistently exceeds recommendations, having a potential negative impact on newborns' development. This study aimed to evaluate the impact of multimodal interventions on noise reduction in a level 3 neonatal intensive care unit. This was a quality-improvement monocentric study, conducted from February 2022 to May 2023. Interventions included a multiprofessional reflection on ways to reduce noise, a staff training, and a modification of the alarms' thresholds. Noise was evaluated before and after intervention using the number of noise peaks ≥ 45 dB/day, and the number of alarms/patient/day. Peaks ≥ 45 dB/day significantly decreased by 48% from before to after intervention (mean number (SD) 396.4 (152.7) versus 204.8 (64.6), p < 0.001). The mean number of ≥ 50 dB/day decreased from 110.0 (57.9) to 48.8 (22.4). The number of alarms decreased peaks from 257 alarms/patient/day before intervention to 134 alarms/patient/day after intervention.

conclusionA multimodal intervention focused on noise reduction was followed by a significant decrease in noise pollution in a level 3 NICU. Multicenter studies on the impact of interventions to reduce noise pollution on short- and long-term outcomes of preterm newborns are required to confirm these results. SUMMARY: In neonatal intensive care units, sound environment remains above noise recommendations all around the world despite evidence showing that exceeding noises can have negative effects on both patients and staff. A multi-professional reflection on noise reduction, a staff training, and a modification of patients' alarms decreased noise pollution in a neonatal intensive care unit. WHAT IS KNOWN: • Noise levels in NICUs consistently exceed international recommendations, potentially harming the neurodevelopment of preterm infants and increasing staff stress. WHAT IS NEW: • A multimodal approach (staff training, alarm threshold adjustment, and collective reflection) significantly reduced noise peaks over 45dB and the number of daily alarms per patient.

Indexed as

Intensive Care Units, NeonatalNoiseQuality ImprovementClinical AlarmsFemaleHumansInfant, NewbornMaleAlarmsDevelopmental careHealth staffNeurodevelopmentNoisePreterm

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.