Evidence map›Paper›PMID 42454664›Full record

ArticleLasers in surgery and medicine2026

Soft Tissue Safety Assessment of Pulsed Solid-State Thulium:YAG Versus Holmium:YAG Lasers: A Quantitative Porcine Model Simulation.

Dennis Buente, Rodrigo Suarez-Ibarrola, Shane O'Sullivan, Arkadiusz Miernik, Ralf Petzold

Abstract readComparative Study
In one paragraph

Article in Lasers in surgery and medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Dennis BuenteDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Baden-Württemberg, Germany.ORCID https://orcid.org/0000-0003-0561-9980
Rodrigo Suarez-IbarrolaDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Baden-Württemberg, Germany.ORCID https://orcid.org/0000-0001-5725-8780
Shane O'SullivanDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Baden-Württemberg, Germany.ORCID https://orcid.org/0000-0003-4287-7380
Arkadiusz MiernikDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Baden-Württemberg, Germany.ORCID https://orcid.org/0000-0001-5894-9647
Ralf PetzoldDepartment of Urology, Faculty of Medicine, University of Freiburg - Medical Centre, Freiburg, Baden-Württemberg, Germany.ORCID https://orcid.org/0000-0002-8033-8858

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesLaser lithotripsy carries an inevitable risk of collateral tissue injury. This study compared the safety profiles of pulsed Holmium:YAG and Thulium:YAG lasers by examining their effects on soft tissue under laser settings relevant to lithotripsy, using ex vivo porcine kidney models.

methodsDirect laser impacts were applied to porcine renal parenchyma and pelvis at constant fiber movements and clinical laser settings (0.2-3.5 J, 10-40 Hz, 2-40 W), with high-power extensions for the Thulium:YAG laser up to 80 W/200 Hz. From 560 histological sections, coagulation and cutting depths were measured and clustered.

resultsAt equivalent power, the Thulium:YAG laser operated with longer pulses than Holmium:YAG, reducing pulse energy per time (pulse power ≤ 3362 vs. ≤ 7777 W). Holmium:YAG laser produced deeper lacerations up to 9.3 mm in renal parenchyma, compared to 5.0 mm with the Thulium:YAG laser. In renal pelvis, maximal cut depth was 3.6 mm with Holmium:YAG-twice as that observed with the Thulium:YAG. While pulse power was a primary determinant for soft tissue damage, high frequencies (100-200 Hz) did not elevate it. Cluster analysis identified laser-specific damage profiles: Thulium:YAG favored coagulative damage at limited depths, whereas Holmium:YAG induced deep lacerations with limited coagulation and tissue detachment.

conclusionSoft tissue safety and complication risk depend on laser parameters and choice of technology. Reduced pulse powers maximize safety, instead pulse frequency seems safe to elevate for improved efficiency. At power levels beyond 20 W, Thulium:YAG benefited from longer pulses showing safer profiles, with shallower penetration and more reliable coagulation compared to Holmium:YAG.

Indexed as

KidneyLasers, Solid-StateLithotripsy, LaserSoft Tissue InjuriesThuliumAnimalsModels, AnimalSwineThuliumlaser parameterlaser pulse powerlithotripsypulsed thulium laserretrograde intrarenal surgerysoft tissue damage

Identifiers

PMID42454664
PMCPMC13649090

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.