ArticlePolymers2026
High-Performance Integrated Self-Powered PNP Hydrogel Sensor for Wearable Human Monitoring.
Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
With the rapid advancement of wearable technologies, high-performance flexible sensors have garnered significant research interest. This study presents a PAM-5 hydrogel characterized by exceptional tensile strain (425%), superior compressive modulus (325 kPa), and notable ionic conductivity (1.1 S/m), serving as a robust mechanical framework and electrical foundation for developing advanced sensors. The PNP-5 integrated hydrogel sensor fabricated from this material demonstrates an extensive sensing range (2-53 kPa), remarkable sensitivity, and rapid response time (~321 ms), with its outstanding performance attributed to the synergistic structural design. Furthermore, the sensor exhibits excellent durability, maintaining consistent voltage output (~6.5 mV) across 1000 compression cycles, confirming its long-term operational stability. Through real-time monitoring of physiological signals and biomechanical movements including finger bending, respiration, and grasping, combined with spatial pressure mapping experiments using a 5 × 5 array touchpad, the device's potential applications in wearable sensing platforms and human-machine interface systems are effectively demonstrated. This self-powered hydrogel sensor not only advances the performance metrics of flexible electronic devices but also establishes a solid experimental basis for future development of intelligent materials in health monitoring and interactive technologies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.