Evidence map›Paper›PMID 42452029›Full record

ArticlePolymers2026

Optimizing Salt Concentration for Reliable Aqueous Size-Exclusion Chromatography of Water-Soluble Polymers.

Lilian Lin, Gregory T Russell, Heon E Park

Abstract read
In one paragraph

Article in Polymers, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Lilian LinDepartment of Chemical and Paper Engineering, Western Michigan University, Kalamazoo, MI 49008, USA.ORCID 0000-0002-0918-1421
Gregory T RussellSchool of Physical and Chemical Sciences, University of Canterbury, Christchurch 8041, New Zealand.ORCID 0000-0002-6773-1428
Heon E ParkDepartment of Chemical and Paper Engineering, Western Michigan University, Kalamazoo, MI 49008, USA.ORCID 0000-0003-2750-9539

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Size-exclusion chromatography (SEC) or gel-permeation chromatography (GPC) is an essential tool for determining the molecular weight and polydispersity of water-soluble polymers, including biopolymers used in hydrogels, sealants, bioinks, and other biomedical materials. However, aqueous SEC of polyelectrolytes, i.e., charged polymers, is often complicated by non-size interactions among polymer chains, porous column beads, pore surfaces, frits, tubing, and mobile phase. Salt addition to eluent is commonly used to screen these interactions, but the minimum salt concentration required to restore reliable SEC behavior remains poorly defined, and excessive salt may introduce tailing, refractive-index artifacts, deposits, or instrument concerns. In this study, aqueous SEC with refractive index (RI) and right-angle light scattering (RALS) detection was used to evaluate the effect of salt (Na2SO4) concentration on poly(ethylene oxide) (PEO), a nominally neutral reference standard polymer, and sodium alginate as a model anionic biopolymer. PEO retained a single bell-shaped peak across the tested salt range, but its elution volume and SEC/RALS-derived molecular weights varied slightly with salt concentration, showing that even a nominally neutral reference polymer is affected by mobile-phase conditions. Alginate showed much stronger salt dependence: eluent at very low salt concentration produced broad, noisy, and convoluted chromatograms, whereas increasing salt concentration progressively narrowed the main peak. The first condition that produced a clear, approximately symmetric RI/RALS main peak was 6.25×10-3 M Na2SO4, identifying it as the minimum effective salt concentration for this alginate/column/instrument system. To rigorously validate these observations, we propose a set of both qualitative and quantitative peak analyses that objectively confirm the optimal mobile-phase conditions. Ultimately, these results provide a practical workflow for identifying the minimum effective salt concentration required for reliable SEC analysis of water-soluble polymers.

Indexed as

anionic polymerdn/dcgel-permeation chromatography (GPC)light scattering (LS)molecular weightnon-size-exclusion interactionsoptimized salt concentrationpolymer–column interactionssodium alginatewater-soluble polymer

Identifiers

PMID42452029
PMCPMC13364055

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.