ArticleSensors (Basel, Switzerland)2026
High-Precision Rotation Axis Calibration of Line-Structured Light Measurement System Using a Stepped Cylinder.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Line-structured light sensors have the advantages of simple structure, low cost, and high precision. Integrating the sensor with a turntable is an important strategy to achieve complete results of complex surfaces. To enhance measurement accuracy, we proposed a rotation axis calibration method using a stepped cylinder. Coefficients of the laser plane are firstly optimized based on the principle of cross-ratio invariance to ensure the sensor's own accuracy. At each rotational angle, the laser plane intersects the cylinder, and corner points on the edges are extracted as feature points. Subsequently, an objective function is established by minimizing the average distance between rotated feature points and ideal circles and is solved using sequential quadratic programming method. After optimization, the average diameter error of the stepped cylinder is reduced by more than 90%. The relative errors of other typical features (ball diameter, cylinder diameter, groove depth) are all less than 0.15%. Measurement results of complex objects with different materials are also successfully obtained with their small features clearly observable.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.