ArticleSensors (Basel, Switzerland)2026
Depth-Sensitive Optical Sensing for Non-Invasive Measurement of Human Muscle Activity.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
Abstract
Human muscle anatomy consists of multiple layers, each contributing to movement through complex patterns of activation. Conventional non-invasive sensing techniques, such as surface electromyography (sEMG) and mechanomyography (MMG), primarily capture aggregate muscle activity and provide limited depth-dependent information. As different movements may involve distinct combinations of superficial and deeper muscles, access to depth-dependent information could improve the discrimination of motion patterns that are difficult to distinguish using surface measurements alone. To address this limitation, we developed an optical sensor capable of depth-sensitive measurement using near-infrared light. The sensor comprises a light source and an array of photodetectors arranged at six source-detector distances (SDDs) ranging from 12 to 48 mm within a compact wearable module. Two experiments were conducted to evaluate the sensor. First, depth sensitivity was investigated using Monte Carlo simulations and phantom experiments, demonstrating distinct sensitivity profiles for different SDDs and providing preliminary evidence of depth-dependent sensing. Second, the sensor was attached to the forearm to measure signals during nine hand and wrist movements. Machine learning models were evaluated for motion classification, with Linear Discriminant Analysis (LDA) achieving the highest performance. Using all six SDD channels, an average classification accuracy of 87.5% was achieved across 10 subjects. An ablation study evaluating all 63 possible channel combinations further showed that classification performance improved systematically with the inclusion of multiple SDD channels, indicating that measurements obtained at different sensing depths provide complementary information for motion discrimination. These results demonstrate the feasibility of multi-SDD optical sensing for capturing depth-dependent physiological information and highlight its potential as a compact, non-invasive sensing approach for wearable human-machine interface applications.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.