Evidence map›Paper›PMID 42451314›Full record

ArticleSensors (Basel, Switzerland)2026

Large-Diameter Diaphragm Fabry-Pérot Interferometer for High-Sensitivity Temperature Sensing Using a Hermetically Sealed Tunable Medium: Up to 190 nm/K.

Anthony Weir, Dubhaltach Mac Lochlainn, Helio Musselwhite-Veitch, Gerard Dooly, Dinesh Babu Duraibabu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Anthony WeirCenter for Robotics and Intelligent Systems (CRIS), Department of Electronic and Computer Engineering, University of Limerick, V94 T9PX Limerick, Ireland.ORCID 0009-0004-9861-2482
Dubhaltach Mac LochlainnNSAI National Metrology Laboratory, Griffith Avenue Ext., Glasnevin, D11 E527 Dublin, Ireland.
Helio Musselwhite-VeitchCenter for Robotics and Intelligent Systems (CRIS), Department of Electronic and Computer Engineering, University of Limerick, V94 T9PX Limerick, Ireland.
Gerard DoolyCenter for Robotics and Intelligent Systems (CRIS), Department of Electronic and Computer Engineering, University of Limerick, V94 T9PX Limerick, Ireland.ORCID 0000-0002-7589-1384
Dinesh Babu DuraibabuDepartment of Mechatronic Engineering, School of Engineering and Design, Atlantic Technological University, Ash Ln, Ballytivnan, F91 YW50 Sligo, Ireland.ORCID 0000-0003-2009-9709

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This paper presents a proof-of-concept investigation into a novel hermetically sealed tunable-medium Extrinsic Fabry-Pérot Interferometer (EFPI) temperature sensor architecture. A series of tuneable-sensitivity EFPI temperature sensors is demonstrated, comprising a large-diameter fused silica diaphragm with a 800 μm diameter, significantly exceeding conventional designs (typically ∼125 μm), with polished diaphragm thicknesses ranging from 28 to 49 μm, housed in hermetically sealed rigid melting point capillaries with a 1.8 mm internal diameter. By exploiting thermally induced pressure differentials generated by a tunable Krytox GPL 105 oil/air fill fraction within the sealed rigid cavity, the sensors demonstrate a continuously tuneable sensitivity design space spanning 0.45 to 190 nm/K. An exact nonlinear thermal pressure model is derived and validated, replacing the linearised approximation which is shown to be inapplicable at fill fractions approaching unity. The low-sensitivity configuration (0.45 nm/K) was characterised at the National Standards Authority of Ireland (NSAI) National Metrology Laboratory against ITS-90 fixed points: the Triple Point of Water (273.16 K) and the Gallium Fixed Point (302.9146 K), with traceability to the International Temperature Scale of 1990 (ITS-90), yielding an instrument-limited resolution of <1.1 mK, consistent with the metrological validation environment. The high-sensitivity configurations (21 and 190 nm/K) were characterised on a laboratory bench, achieving instrument-limited theoretical resolutions of <24 μK and <2.6 μK respectively, pending future metrological validation. The 190 nm/K sensitivity represents an improvement of approximately 21.7× over the closest directly comparable prior Citationutilised fusion splicing and manual polishing. Future development priorities include metrological validation of the high-sensitivity configurations, long-term stability characterisation, thermal cycling, and progression towards an all-glass hermetically sealed construction.

Indexed as

diaphragmEFPIextrinsic Fabry–Pérot interferometryhermetically sealed cavitykrytox GPL-105optical fibre sensortemperature sensortuneable sensitivity

Identifiers

PMID42451314
PMCPMC13363969

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.