ArticleSensors (Basel, Switzerland)2026
A Robust and Highly Integrated Laser Doppler Velocimeter for High-Precision Velocity Measurement of Hot-Rolled Bars Under Thermal Radiation.
Article in Sensors (Basel, Switzerland), 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Real-time, non-contact velocity measurement of hot-rolled bars is critical for metallurgical process control, but conventional laser Doppler velocimetry (LDV) systems often fail in these environments. The intense broadband thermal radiation from targets up to 1000 °C, coupled with severe surface depolarization, overwhelms weak scattered signals in high-speed (up to 40 m/s) rolling zones. To address this issue, we developed a fully integrated, thermal-radiation-resistant LDV sensing system. Hardware optimization was achieved by eliminating polarized-light transmission and adopting a parallel-beam design, which significantly enlarges the laser overlap area and increases detection depth. Furthermore, a 1550 nm laser (100 mW) was coaxially combined with a 10 nm narrow-band filter to isolate the thermal background and boost signal strength. A customized workflow utilizing continuous Fourier transform (CFT) spectral refinement and energy centroid estimation was implemented to precisely extract the true Doppler shift. Performance evaluations show the system achieves an excellent signal-to-noise ratio (SNR) of 29,532. Allan variance analysis confirms a stable detection sensitivity of 0.003 m/s (0.1 s integration time), a local short-to-medium-term optimal limit of 1.6 × 10
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.