ArticlePhysical and engineering sciences in medicine2026
FSI analysis of synthetic graft for coronary bypass flow: numerical optimization of geometric parameters.
Article in Physical and engineering sciences in medicine, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Coronary artery disease, a leading cause of mortality worldwide, often necessitates bypass surgery to restore blood flow and prevent myocardial infarction. In this procedure, a graft is sutured to the coronary artery, bypassing the occluded region. Synthetic grafts are a viable option for such surgeries. This study optimizes the geometric design of synthetic grafts by determining the ideal connection angle and diameter using a genetic algorithm. The algorithm minimizes the Time-Averaged Wall Shear Stress (TAWSS) as the cost function. Parametric variations were applied, with the diameter ranging from 2.5 mm to 4 mm and the connection angle from 20° to 85°. The optimal model identified a graft diameter of 4 mm and a connection angle of 61°. Computational fluid dynamics (CFD) and fluid-structure interaction (FSI) analyses of the optimal design revealed that elevated TAWSS was confined to a small region at the graft-coronary artery junction and the toe of the anastomosis. These findings underscore the importance of optimizing graft geometry to enhance the hemodynamic performance, efficiency, and durability of synthetic grafts in bypass surgeries.
Indexed as
Identifiers
42446841What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.