Evidence map›Paper›PMID 42445708›Full record

ArticleReports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology2026

Accuracy assessment of a hybrid deep learning and image processing approach for lung CT segmentation in external radiotherapy.

Hamza Sekkat, Abdellah Khallouqi, Yasmina Berrada, Mohammed Talbi, Ahmed Bannan, Oussama El Mouden, Abdellah Halimi, Youssef Madkouri, Omar El Rhazouani

Abstract read
In one paragraph

Article in Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology, 2026. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Hamza SekkatSciences and Engineering of Biomedicals and Biophysics Laboratory, Higher Institute of Health Sciences, Hassan 1 University, Settat, Morocco.
Abdellah KhallouqiSciences and Engineering of Biomedicals and Biophysics Laboratory, Higher Institute of Health Sciences, Hassan 1 University, Settat, Morocco.
Yasmina BerradaDepartment of Radiotherapy, International Clinic of Settat, Settat, Morocco.
Mohammed TalbiHigher Institute of Nursing Professions and Health Techniques, Rabat, Morocco.
Ahmed BannanSciences and Engineering of Biomedicals and Biophysics Laboratory, Higher Institute of Health Sciences, Hassan 1 University, Settat, Morocco.
Oussama El MoudenSciences and Engineering of Biomedicals and Biophysics Laboratory, Higher Institute of Health Sciences, Hassan 1 University, Settat, Morocco.
Abdellah HalimiSciences and Engineering of Biomedicals and Biophysics Laboratory, Higher Institute of Health Sciences, Hassan 1 University, Settat, Morocco.
Youssef MadkouriLaboratory of Electronic Systems, Information Processing, Mechanics and Energetics, Faculty of Sciences, Ibn Tofail Kenitra University, Kenitra, Morocco.
Omar El RhazouaniSciences and Engineering of Biomedicals and Biophysics Laboratory, Higher Institute of Health Sciences, Hassan 1 University, Settat, Morocco.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Accurate lung segmentation in computed tomography (CT) is a fundamental step for numerous clinical applications, including radiotherapy planning and thoracic disease diagnosis. Manual segmentation, however, remains time-consuming and operator-dependent. This study aims to develop a fully automated segmentation framework combining a well-structured pipeline of image processing techniques with a deep learning model based on a U-Net architecture and a pre-trained VGG16 encoder. Materials and methods: Ninety anonymized thoracic CT scans, including lung and breast cancer patients, were collected, pre-processed and used to generate binary lung masks using a custom Python pipeline. The dataset was split patient-wise into training (70%), validation (15%) and testing (15%) subsets. The model was trained using binary crossentropy loss, the Adam optimizer and data augmentation strategies to improve generalization. Results: High correlations were observed between automatically computed lung volumes and mean Hounsfield units (HU) compared to the treatment planning system (TPS) references (R Conclusions: The proposed VGG16-based U-Net model demonstrates high accuracy and robustness in segmenting lungs from thoracic CT scans, achieving ~95% DSC and ~99% pixel-wise accuracy. It effectively replaces manual segmentation with a fully automated, scalable solution. This framework streamlines lung segmentation in clinical radiotherapy workflows, reducing operator variability and time consumption.

Indexed as

deep learningexternal radiotherapylung segmentation

Identifiers

PMID42445708
PMCPMC13364373

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.